background image

Make sure that the gas supply

pressure of the appliance obeys the

recommended values. The adjustable

connection is fixed to the

comprehensive ramp by means of a

threaded nut G 1/2". Screw the parts

without force, adjust the connection in

the necessary direction and tighten

everything.

A

B

C

A. End of shaft with nut

B. Washer supplied with the appliance

C. Elbow supplied with the appliance

Liquid gas

Use the rubber pipe holder for liquid gas. Always

engage the gasket. Then continue with the gas

connection.
The flexible pipe is prepared for apply when:
• it can not get hot more than room temperature,

higher than 30°C;

• it is no longer than 1500 mm;

• it shows no throttles;

• it is not subject to traction or torsion;

• it does not get in touch with cutting edges or

corners;

• it can be easily examined in order to make sure

its condition.

The control of preservation of the flexible pipe

consists in checking that:
• it does not show cracks, cuts, marks of burnings

on the two ends and on its full length;

• the material is not hardened, but shows its

correct elasticity;

• the fastening clamps are not rusted;

• expired term is not due.
If one or more defects are visible, do not repair the

pipe, but replace it.

WARNING! When installation is

complete, make sure that the seal of

each pipe fitting is correct. Use a

soapy solution, not a flame!

INJECTORS REPLACEMENT
1. 
Remove the pan supports.

2. Remove the caps and crowns of the burner.

3. With a socket spanner 7 remove the injectors

and replace them with the ones which are

necessary for the type of gas you use (see

table in "Technical Data" chapter).

4. Assemble the parts, follow the same procedure

backwards.

5. Replace the rating plate (it is near the gas

supply pipe) with the one for the new type of

gas supply. You can find this plate in the

package supplied with the appliance.

If the supply gas pressure is changeable or

different from the necessary pressure, you must fit

an applicable pressure adjuster on the gas supply

pipe.

ADJUSTMENT OF MINIMUM LEVEL
To adjust the minimum level of the burners:
1. Light the burner.

2. Turn the knob on the minimum position.

3. Remove the knob . 

4. With a thin screwdriver, adjust the bypass

screw position (A).

A

5. If you change:

• from natural gas G20 20 mbar to liquid gas,

fully tighten the bypass screw in.

• from liquid gas to natural gas G20 20 mbar,

undo the bypass screw approximately 1/4

of a turn (1/2 of a turn for Triple Crown

burner).

WARNING! Make sure the flame does

not go out when you quickly turn the

knob from the maximum position to the

minimum position.

ELECTRICAL CONNECTION
• Make sure that the rated voltage and type of

power on the rating plate agree with the voltage

and the power of the local power supply.

• This appliance is supplied with a mains cable. It

has to be supplied with a correct plug which

can hold the load that the rating plate rates.

Make sure that you install the plug in a correct

socket.

• Always use a correctly installed shockproof

socket.

11

Содержание ZGH78534XA

Страница 1: ...GETTING STARTED EASY User Manual ZGH78534XA EN User Manual Hob DZ LY MA TN ...

Страница 2: ...sons with very extensive and complex disabilities shall be kept away unless continuously supervised Children of less than 3 years of age should be kept away unless continuously supervised Do not let children play with the appliance Keep all packaging away from children and dispose of it appropriately Keep children and pets away from the appliance when it operates or when it cools down Accessible p...

Страница 3: ...route the mains cable make sure that the cable doesn t come into direct contact for example using insulating sleeving with parts that can reach temperatures of more than 50 C above room temperature WARNING Use only hob guards designed by the manufacturer of the cooking appliance or indicated by the manufacturer of the appliance in the instructions for use as suitable or hob guards incorporated in ...

Страница 4: ... plug after the installation If the mains socket is loose do not connect the mains plug Do not pull the mains cable to disconnect the appliance Always pull the mains plug Use only correct isolation devices line protecting cut outs fuses screw type fuses removed from the holder earth leakage trips and contactors The electrical installation must have an isolation device which lets you disconnect the...

Страница 5: ...for example increasing the level of mechanical ventilation where present This appliance is for cooking purposes only It must not be used for other purposes for example room heating Do not let acid liquids for example vinegar lemon juice or limescale remover touch the hob This can cause matt patches Discoloration of the enamel or stainless steel has no effect on the performance of the appliance CAR...

Страница 6: ... 3 Semi rapid burner 4 Control knobs CONTROL KNOB Symbol Description no gas supply off position ignition position maximum gas supply Symbol Description minimum gas supply DAILY USE WARNING Refer to Safety chapters BURNER OVERVIEW A B C A Burner cap and crown B Thermocouple C Ignition candle 6 ...

Страница 7: ... the control knob turn it into off position and try to light the burner again after minimum 1 minute CAUTION In the absence of electricity you can ignite the burner without electrical device in this case approach the burner with a flame turn the control knob counter clockwise to maximum gas supply position and push it down Keep the control knob pushed for equal or less than 10 seconds to let the t...

Страница 8: ...s steel Wash stainless steel parts with water and then dry them with a soft cloth To remove burnt food fat and stubborn stains let them soak in a small amount of mild detergent for a few minutes before cleaning Use cleaning products designed specifically for cleaning stainless steel in order to protect the steel surfaces Do not use cleaning products containing corrosive chemicals such as chlorides...

Страница 9: ...ctly Check if the hob is correctly connected to the electrical supply The fuse is blown Make sure that the fuse is the cause of the malfunction If the fuse is blown again and again contact a qualified electrician Burner cap and crown are placed incorrectly Place the burner cap and crown correctly The flame extinguishes immedi ately after ignition Thermocouple is not heated up sufficiently After li...

Страница 10: ... you install the hob write down the information bellow from the rating plate The rating plate is on the bottom of the hob Model PNC Serial number GAS CONNECTION WARNING The following instructions about installation connection and maintenance must be carried out by qualified personnel in compliance with standards and local regulations in force Choose fixed connections or use a flexible pipe in stai...

Страница 11: ...s 2 Remove the caps and crowns of the burner 3 With a socket spanner 7 remove the injectors and replace them with the ones which are necessary for the type of gas you use see table in Technical Data chapter 4 Assemble the parts follow the same procedure backwards 5 Replace the rating plate it is near the gas supply pipe with the one for the new type of gas supply You can find this plate in the pac...

Страница 12: ...ke sure that you connect the blue neutral cable to the terminal with a letter N on it Connect the brown or black phase cable to the terminal which has a letter L Keep the phase cable connected at all times CONNECTION CABLE To replace the connection cable use only the special cable or its equivalent The cable type is H05V2V2 FT90 Make sure that the cable section is applicable to the voltage and the...

Страница 13: ... intervention is necessary Kitchen unit with door min 20 mm max 150 mm 30 mm 60 mm B A A Removable panel B Space for connections Kitchen unit with oven The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit TECHNICAL DATA HOB DIMENSIONS Width 745 mm Depth 515 mm BYPASS DIAMETERS BURNER Ø BYPASS 1 100 mm Triple Cro...

Страница 14: ...ATURAL GAS G20 20 mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK Triple Crown 4 0 1 4 146 Semi rapid 2 0 0 45 96 Auxiliary 1 0 0 33 70 GAS BURNERS FOR LPG G30 G31 28 30 37 mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK NOMINAL GAS FLOW g h G30 28 30 mbar G31 37 mbar Triple Crown 4 0 1 4 98 291 286 Semi rapid 2 0 0 45 71 145 143 Auxiliary 1 0 0 33 50 73 71 ENERGY EFFICIENCY ...

Страница 15: ...le to the size of burners Center the pot on the burner When you heat up water use only the amount you need If it is possible always put the lids on the cookware When the liquid starts to boil turn down the flame to barely simmer the liquid If it is possible use a pressure cooker Refer to its user manual ENVIRONMENTAL CONCERNS Recycle materials with the symbol Put the packaging in relevant containe...

Страница 16: ...WWW ZANUSSI COM SHOP 867329995 C 512017 ...

Отзывы: