4. With a thin screwdriver, adjust the bypass

screw position (A).

A

5. If you change:

• from natural gas G20 20 mbar to liquid gas,

fully tighten the bypass screw in.

• from liquid gas to natural gas G20 20 mbar,

undo the bypass screw approximately 1/4

of a turn (1/2 of a turn for Multi Crown

burner).

6. Reassemble the gasket and the knob.

WARNING! Make sure the flame does

not go out when you quickly turn the

knob from the maximum position to the

minimum position.

ELECTRICAL CONNECTION
• Do not pull the mains cable to disconnect the

appliance. Always pull the mains plug (if

applicable).

• The appliance must not be connected with an

extension cable, an adapter or a multiple socket.

There is a risk of fire.

• Do not let the power cable to heat up to a

temperature of more than 90° C. The cable

should be guided by means of clamps fixed to

the side of the cabinet, in order to avoid any

contact with the equipment beneath the

cooktop.

• Make sure that there is access to the mains plug

after the installation.

Electrical Requirements

Permanent electrical installation must agree with

the latest I.E.E. Regulations and local Electricity

Board regulations. For your own safety the

installation must be done by a qualified electrician

(e.g. your local Electricity Board, or a contractor

who is on the roll of the National Inspection Council

for Electrical Installation Contracting [NICEIC]).

The manufacturer refuses to be

held responsible, if these safety

measures are not abided by.

Supply connections

This hob has to be connected to 220-240 V (~

50/60 Hz ) electricity supply.
The hob has a terminal block which is

marked as follows:
• L — Live terminal

• N — Neutral terminal

 or E — Earth terminal

Before carrying out the connection, make sure:
1. The limiter valve and the electrical system can

take the appliance load (see the rating plate)

2. The supply system is equipped with an efficient

earth connection in compliance with the current

standards and regulations

3. The outlet or omnipolar switch used for

connection is easily accessible with the

appliance installed.

The appliance is supplied with a 3 core flexible

power cable with a 3 amp plug. If it is necessary to

change the fuse, use a 3 amp ASTA-approved (BS

1362) fuse.

12

Содержание ZGH66424BB

Страница 1: ...GETTING STARTED EASY User Manual ZGH66424BB ZGH66424XX EN User Manual Hob GB IE ...

Страница 2: ...sons with very extensive and complex disabilities shall be kept away unless continuously supervised Children of less than 3 years of age should be kept away unless continuously supervised Do not let children play with the appliance Keep all packaging away from children and dispose of it appropriately Keep children and pets away from the appliance when it operates or when it cools down Accessible p...

Страница 3: ...ou route the mains cable make sure that the cable doesn t come into direct contact for example using insulating sleeving with parts that can reach temperatures of more than 50 C above room temperature WARNING Use only hob guards designed by the manufacturer of the cooking appliance or indicated by the manufacturer of the appliance in the instructions for use as suitable or hob guards incorporated ...

Страница 4: ... plug after the installation If the mains socket is loose do not connect the mains plug Do not pull the mains cable to disconnect the appliance Always pull the mains plug Use only correct isolation devices line protecting cut outs fuses screw type fuses removed from the holder earth leakage trips and contactors The electrical installation must have an isolation device which lets you disconnect the...

Страница 5: ...for example increasing the level of mechanical ventilation where present This appliance is for cooking purposes only It must not be used for other purposes for example room heating Do not let acid liquids for example vinegar lemon juice or limescale remover touch the hob This can cause matt patches Discoloration of the enamel or stainless steel has no effect on the performance of the appliance CAR...

Страница 6: ...liary burner 4 Control knobs CONTROL KNOB Symbol Description no gas supply off position ignition position maximum gas supply Symbol Description minimum gas supply DAILY USE WARNING Refer to Safety chapters BURNER OVERVIEW A B D C C D A B A Burner cap B Burner crown C Ignition candle D Thermocouple 6 ...

Страница 7: ...ntrol knob counter clockwise to maximum gas supply position and push it down Keep the control knob pushed for equal or less than 10 seconds to let the thermocouple warm up If the burner accidentally goes out turn the control knob to the off position and try to light the burner again after minimum 1 minute The spark generator can start automatically when you switch on the mains after installation o...

Страница 8: ...nt for a few minutes before cleaning Use cleaning products designed specifically for cleaning stainless steel in order to protect the steel surfaces Do not use cleaning products containing corrosive chemicals such as chlorides do not clean the surface with disinfectants stain or rust removers and immersion cleaners PAN SUPPORTS The pan supports are not resistant to washing in a dishwasher They mus...

Страница 9: ...e spark generator The hob is not connected to an electrical supply or it is con nected incorrectly Check if the hob is correctly connected to the electrical supply The fuse is blown Make sure that the fuse is the cause of the malfunction If the fuse is blown again and again contact a qualified electrician Burner cap and crown are placed incorrectly Place the burner cap and crown correctly The flam...

Страница 10: ...Current Edition For appliances installed in the Republic of Ireland please refer to NSAI Domestic Gas Installation I S 813 Current Editions and the ETCI Rules for Electrical Installations Provision for ventilation Detailed recommendations are contained in the following British Standards Codes Of Practice B S 6172 B S 5440 Par 2 and B S 6891 Current Editions The hob should not be installed in a bed...

Страница 11: ... copper The connection should be suitable for connecting to R 1 2 1 2 BSP male thread When the final connection has been made it is essential that a thorough leak test is carried out on the hob and installation Make sure that the main connection pipe does not exert any strain on the hob If you use flexible metal pipes make sure that they agree to ISO 10380 and ISO 10807 standards Be careful they d...

Страница 12: ...trical Requirements Permanent electrical installation must agree with the latest I E E Regulations and local Electricity Board regulations For your own safety the installation must be done by a qualified electrician e g your local Electricity Board or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting NICEIC The manufacturer refuses to be hel...

Страница 13: ...e use only H03V2V2 F T90 or equivalent type Make sure that the cable section is applicable to the voltage load and the working temperature The yellow green earth wire B must be approximately 2 cm longer than the live and neutral wire A A B 1 Connect the green and yellow earth wire to the terminal which is marked with the letter E or the earth symbol or coloured green and yellow 2 Connect the blue ...

Страница 14: ...mum safety distance of 50 mm to the left or right from the edge of the hob 5 6 7 8 A A supplied bracket 9 CAUTION Install the appliance only on a worktop with flat surface POSSIBILITIES FOR INSERTION The panel installed below the hob must be easy to remove and let an easy access in case a technical assistance intervention is necessary Kitchen unit with door or drawer min 6 mm 14 ...

Страница 15: ...SS 1 100 mm Multi Crown 57 Semi rapid 32 Auxiliary 28 OTHER TECHNICAL DATA TOTAL POW ER Gas original G20 2H 20 mbar 9 kW Gas replace ment G30 3 28 30 mbar 629 g h G31 3 37 mbar 618 g h Electric supply 220 240 V 50 60 Hz 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse Appliance cate gory II2H3 Gas connec tion R 1 2 Appliance class 3 GAS BURNERS FOR NATURAL GAS G20 ...

Страница 16: ... Part 2 1 Rational use of energy General ENERGY SAVING Before use make sure that the burners and pan supports are assembled correctly Use cookware with diameters applicable to the size of burners Center the pot on the burner When you heat up water use only the amount you need If it is possible always put the lids on the cookware When the liquid starts to boil turn down the flame to barely simmer t...

Страница 17: ...17 ...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...WWW ZANUSSI COM SHOP 867345144 C 502017 ...

Отзывы: