10
Installation and Assembly
These hobs can be installed in a kitchen unit with an
opening for insertion whose dimensions are shown in
Fig. 10.
The edge of the cut out must have a minimum distance
from the rear wall of 55 mm.
If there are side walls, or sides of the furniture unit near
the hob, the cut out edges must have a minimum
distance of 150 mm as shown in Fig. 10.
Carry out the building in of the hob as follows:
•
put the relevant sealings, supplied with the hob,
on the edges of the cut out: place them at 8
mm from the front and rear edge and at 50
mm from the side edges, as shown in Fig. 11,
taking care that the sealings meet without
overlapping;
•
place the hob in the cut out, taking care of its
centring;
•
fix the hob with the relevant screws (Fig. 12). The
traction of the screws is able to trace the sealing, any
excess of which can then be easily removed.
The edge of the hob forms a double labyrinth seal which
provides a total guarantee against infiltration of liquids.
Fig. 10
Fig. 11
Fig. 12
FO 2038
FO 0199
a
a) sealing