6
Door reversibility
Before carrying out any work on the appliance,
unplug it from the power socket.
Remove the upper hinge (Fig. 3) and slide the top
door off the middle hinge.
Remove the middle hinge, turn it through 180
°
and
refit it on the opposite side (Fig. 3a) after having
removed the plugs which mask the holes. The plugs
must be refitted in the holes left open on the opposite
side.
Refit the top door and the top hinge. Unscrew the left-
hand levelling foot, which will be refitted on the
opposite side. Unscrew the right-hand levelling foot
(H), the corresponding hinge (I) and the stop (L) and
refit all these on the left-hand side (Fig. 3b).
Reverse the handles after having removed the clip-in
screw covers. The unused holes are masked with
plastic plugs which should be removed and refitted in
the holes left open.
Attention
After completion of the door reversibility operation,
verify that the door gasket is adherent to the cabinet.
If the ambient temperature is cold (i.e. in Winter), the
gasket may not fit perfectly to the cabinet. In that
case, wait for the natural fitting of the gasket or
accelerate this process by heating up the part involved
with a normal hairdrier.
Electrical connection
Before plugging in, ensure that the voltage and
frequency shown on the serial number plate
correspond to your domestic power supply.
Voltage can vary by
±
6% of the rated voltage.
For operation with different voltages, a suitably sized
auto-transformer must be used.
Fig. 3
Fig.
3a
Fig.
3b
Fig.
3c
D185
D045
E
H
I
D537
L
D336
TECHNICAL SPECIFICATION
The technical data is indicated in the rating plate on the left side inside the appliance.
GB