Once the top of the panel has been correctly
positioned, fix it through the holes in the bottom
bracket, without tightening the screws (Fig. 10).
Fig. 10
Check the position again by slackening the screws
and pins then, once the best position has been
obtained, fully tighten all the fixings.
Cover the visible part of the top bracket on the
panel with plastic cover (D), inserting it in the
locations provided in the bracket.
Fig. 11
D471
D472
D
Once the door has ben correctly aligned, tighten the
holding nuts on the fixing brackets and attach the
appliance to the adjacent units and the bottom of
the work surface (Fig. 12).
Fig. 12
If the appliance has been fitted into a space 820 mm
high and the maximum height of the base plate is
100 mm, fit the front cover plate by pushing the two
vertical lugs into the rectangular holes on the
bottom side of the ventilation duct until they click.
The plate can be adjusted backwards or forwards in
the holes (Fig. 13).