Problem and alarm code
Possible cause and solution
The temperature of the water
inside the appliance is too high
or malfunction of the tempera-
ture sensor occurred.
• The lights related to the
programme buttons flash 6
times intermittently.
• An acoustic signal sounds
intermittently.
• Make sure that the temperature of the inlet water does not ex-
ceed 60°C.
• Switch the appliance off and on.
Technical malfunction of the
appliance.
• The lights related to the
programme buttons flash
12 times intermittently.
• An acoustic signal sounds
intermittently.
• Switch the appliance off and on.
The level of water inside the
appliance is too high.
• The lights related to the
programme buttons flash
15 times intermittently.
• An acoustic signal sounds
intermittently.
• Switch the appliance off and on.
• Make sure that the filters are clean.
• Make sure that the outlet hose is installed at the right height
above the floor. Refer to the installation instructions.
The appliance stops and starts
more times during operation.
• It is normal. It provides optimal cleaning results and energy sav-
ings.
The programme lasts too long.
• If the delay start option is set, cancel the delay setting or wait
for the end of the countdown.
• Activating Extra Power increases the programme duration.
Small leak from the appliance
door.
• The appliance is not levelled. Loosen or tighten the adjustable
feet (if applicable).
• The appliance door is not centred on the tub. Adjust the rear
foot (if applicable).
The appliance door is difficult
to close.
• The appliance is not levelled. Loosen or tighten the adjustable
feet (if applicable).
• Parts of the tableware are protruding from the baskets.
Rattling or knocking sounds
from the inside of the appli-
ance.
• The tableware is not properly arranged in the baskets. Refer to
basket loading leaflet.
• Make sure that the spray arms can rotate freely.
The appliance trips the circuit-
beaker.
• The amperage is insufficient to supply simultaneously all the ap-
pliances in use. Check the socket amperage and the capacity
of the meter or turn off one of the appliances in use.
• Internal electrical fault of the appliance. Contact an Authorised
Service Centre.
Once you have checked the appliance, deactivate
and activate the appliance. If the problem occurs
again, contact an Authorised Service Centre.
For alarm codes not described in the table, contact
an Authorised Service Centre.
19