5
ELECTRICAL CONNECTIONS
Any electrical work required to install
this hob and the supply cable should be
carried out by a qualified electrician or
competent person, in accordance with the
current regulations.
THIS COOKER MUST BE EARTHED.
The manufacturer disclaims any
responsibility should these safety
instructions not be carried out.
This cooker is designed to be connected to a
230/400V, 50Hz electrical supply.
To connect to the electricity supply, use cable
type H05 RR-F.
Before switching on, make sure the electricity
supply voltage is the same as that indicated on
the rating plate.
The cooker is supplied without supply cable. A
flexible supply cable must be fitted, in
accordance with the specification gived in the
relevant table no. 1.
In case of a direct connection to the mains you
have to interpose an omnipolar switch a
minimum opening between contacts of 3 mm.
The switch should be sited within 2m of the hob
and be easily accessible upon completion of the
installation.
The yellow-green grounding cable has not to be
interrupted by the switch.
NOTE:
The earth wire should be about 2 cm
longer than the live and neutral wires.
If the supply cord is damaged, it must
be replaced by the manufacturer or its
service agent or a similarly qualified person
in order to avoid a hazard.
After installation and connecting, the
cable must be placed so that it cannot at any
point reach a temperature of more than 50°C
above the ambient temperature.
supply
cable
Before connecting check that:
•
fuse and household electric installation can
bear the charge of the appliance (see rating
plate);
•
The socket or the omnipolar switch used for
connection is easily reachable when the
appliance is installed.
How to proceed?
•
Unscrew and remove the protective cover at
the back of the appliance;
•
Connect the power cord to the terminal of the
cooker according to the table no.1;
•
Fix by means of cable clamp;
•
Make sure that the connection to the terminal
is matching the network power;
•
Remount and screw the protective cover at the
back of the appliance.
Table no. 1
Rated voltage
230V 1N, 230/400V 3N, 230V 3~, 230/400V 2N
Connection type
Single phase
Tri-phase Y 3 ph.
+ neutral
Tri-phase
Tri-phase Y 2 ph. +
neutral
Cable connection to the
terminal plate
1 2 3 4 5
L1
N
PE
3
1
L3
L1
PE
4 5
N
L2
2
L3
5
1 2 3 4
L1
L2
PE
4 5
N
PE
2 3
L2
L1
1
Network voltage
1N/230 V
3N/400 V
3/230 V
2N/400 V
Voltage of heating
elements
230 V
230 V
230 V
230 V
Fusible capacity
20 A
3 x 10 A
3 x 20 A
2 x 10 A
Cable section
3 x 4 mm
2
5 x 2,5 mm
2
4 x 4 mm
2
4 x 2,5 mm
2