Placement
Remove the plastic packaging and install
the cooker in a dry, ventilated room (fig. 15)
not near curtains, paper, alcohol, petrol,
etc…)
The appliance has to be set on a heatproof
soil.
This appliance belongs to class “1” in
matters of protection against overheating of
surrounding surfaces.
It is mandatory to keep 2cm distance to the
furniture walls.
Ventilation
Gas combustion is possible due to the
oxygen in the air (2 m
3
air/h x kW installed
power – check the rating panel of the
cooker).
It is necessary to renew the air and that the
combustion products be discharged.
The air flow must come directly through
openings of external walls having a free
passage of at least 100 cm
2
.
These openings should be realized
preferably positioned near the floor,
opposite the combustion products
discharge. It should not be occluded both
from inside and outside.
Gas connection
Your cooker is delivered adjusted for the
kind of gas stated on the rating plate.
It might be necessary to pass to another
kind of gas, different to the one it is preset
to. Under these circumstances follow the
instructions bellow.
For best efficiency, lowest
consumption and a longer length of life of
your cooker, the manifold gas pressure has
to respect the values shown in table no. 1
The appliance is supplied with Natural gas,
Butane or Propane gas check that from the
pressure regulator, the pressure for Natural
gas is 20 mbar, for Butane is 28-30 mbar
and for Propane 37 mbar.
2 cm
2 cm
59 cm
69 c
m
fig. 15