25
Installation and Servicing
FLUE OUTLET
SECTION 2 - INSTALLATION
Note.
A flat or pitched roof flashing plate (not supplied) is required before proceeding
with the installation of this kit.
This kit is suitable for both flat and pitched
roof terminations, using a concentric flue to
run vertically from the top of the boiler and
terminating above roof level.
Connection to the top of the boiler is made
using the supplied vertical connector.
WEATHER PROOFING
Where the flue passes through the roof line
an adequate seal must be made. This is
achieved by using either:
- Flat roof weather collar
or
- Universal weather collar.
ACCESSORIES
Flue Duct Extension Kits are available for
flue lengths extending beyond 1m. These
packs contain 1m extension ducts and may
be cut to the desired length.
If the offset vertical option is used an elbow
Kit is required.
Soffit Flue Kit supplied as an optional extra.
For a full accessories list refer to page 11, Optional Extras.
Flue
duct
support
Vertical
Connector
Flue
duct
support
90
o
elbow
UIN 203130
45
o
elbow
UIN 203131
Roof Flue Extension Duct
UIN 211037 (500mm)
UIN 203129 (1000mm)
UIN 211038 (2000mm)
Flue Terminal
UIN 211039
Flue Seal Collar - Flat Roof
UIN 152259
Flue Seal Collar - Tile Roof
UIN 152258
Soffit Flue Kit
UIN 211302
Vertical connector
UIN 208175
2.13 ROOF FLUE KIT CONTENTS / OPTIONS
2.12 FITTING THE OPTIONAL ROOF FLUE KIT (Flat or Pitched) & SOFFIT FLUE KIT
Содержание ULTRA COMBI 30
Страница 4: ...4 Installation and Servicing ...
Страница 6: ...6 Installation and Servicing ...
Страница 62: ...62 Installation and Servicing SECTION 6 BENCHMARK COMMISSIONING ...
Страница 68: ...68 NOTES Installation and Servicing ...
Страница 69: ...69 NOTES Installation and Servicing ...
Страница 70: ...70 NOTES Installation and Servicing ...
Страница 71: ...71 NOTES Installation and Servicing ...