18
Electrical connection
The unit is preset to work with a voltage of single phase
230 V.
Before making the connection make sure that: the
energy power available in the user's house is sufficient
for the normal supply of this appliance (see rating plate).
The unit is correctly connected to earth through a
suitable plug and according to the installation country
Laws.
The socket or the omnipolar switch used for the
connection must be easily reached with the installed
appliance. The appliance is supplied without electric
cord: consequently, you have to install a plug fit for the
load shown in the serial number plate. The plug has to
be connected to an adequate socket.
If you wish to directly connect to the mains, you have to
interpose an omnipolar switch with a minimum opening
between contacts of 3 mm, between the unit and the
mains, complying with the existing regulations. The
brown live wire (originating from the clamp of the cooker
junction box) must always be connected to the phase
of the mains supply. In any case, the supply cord must
be positioned in such a way as it doesn't reach in any
point a temperature higher by 50°C than the room tem-
perature.
Replacement of supply cable
Should the supply cord need to be replaced, use only
cables of the following types: H07 RN-F, H05 RN-F, H05
RR-F, H05 VV-F, H05 V2V2-F (T90), H05 BB-F
Moreover, it is necessary that the yellow/green earth
wire is about 2cm longer than the live and neutral ones
(Fig. 29).
After the connection, test the heating elements for about
3 minutes to ensure that they are working correctly.
The manufacturer refuses any responsability in
cases where normal safety measures are not
observed.
Fig. 29
FO 0480
Ground (yellow - green)
Neutral
wire
Phase
Содержание Gas and mixed fuel cookers
Страница 1: ...INSTRUCTION BOOKLET GAS AND MIXED FUEL COOKERS ...
Страница 20: ...35669 8003 02 01 Grafiche MDM Forlì ...