Levelling the appliance
Adjustment to suit floor conditions or height
is obtained by rotating clockwise or anti
clockwise the feet at the front and rear of the
appliance. A spirit level should be placed on
one of the shelves to confirm the appliance
is correctly levelled.
Connecting to gas supply
This appliance is designed to be installed
with an appliance flexible connection only.
Supply piping should not be less than R
3
/8.
Connection is made to the Rc ½ (½” B.S.P.)
female threaded entry pipe located just
below the hotplate level on the rear left hand
side of the appliance.
NOTE: ONLY LIQUID
SEALANTS TO BE USED WHEN INLET
GAS PIPE IS FITTED I.E.: DO NOT USE
P.T.F.E. SEALANT TAPE.
Carry out a gas
tightness test after connecting to the gas
supply. The gas bayonet connector must be
fitted in the shaded area indicated in Fig.2.
Take into account that it must be possible to
pull the appliance forward sufficiently.
Ensure the hose does not become trapped
when pushing the appliance into position.
IMPORTANT: FLEXIBLE TUBING USED
MUST COMPLY WITH BS.669 CURRENT
EDITION.
LPG Flexible connections must be a type
suitable for L.P.G and capable of operation
up to 50 mbar and carry a red stripe, band or
label.
Fig.2.