8
INJECTORS REPLACEMENT
•
Remove the pan supports.
•
Remove the burner's caps and crowns.
•
With a socket spanner 7 unscrew and remove the
injectors (Fig. 6), and replace them with the ones
required for the type of gas in use (see table 2).
•
Reassemble the parts, following the same procedu-
re backwards.
•
Replace the rating label (placed near the gas supply
pipe) with the relevant one for the new type of gas
supply. You can find this label in the package of the
injectors supplied with the appliance.
Should the feeding gas pressure be different or
variable compared with the required pressure, an
appropriate pressure adjuster must be fitted on the gas
supply pipe, in compliance with the rules in force.
7. Adaptation to different types of gas
Fig. 6
FO 0392
ADJUSTMENT OF MINIMUM LEVEL
To adjust the minimum level of the burners, proceed as
follows:
•
Light the burner.
•
Turn the knob on the minimum position.
•
Remove the knob.
•
With a thin screwdriver, adjust the by-pass screw
positioned beside or inside the tap rod (see Fig. 7 -
lett. "a"). If changing from natural gas to LPG,
completely tighten clockwise the screw. When
converting from LPG to natural gas unscrew about
one-fourth turn by-pass pin.
•
Finally check the flame does not go out when quickly
turning the knob from the maximum position to the
minimum position.
This procedure can easily be carried out, anyhow the
hob has been positioned or built in the working top.
BURNER
NORMAL
REDUCED
NORMAL
POWER
POWER
POWER
kW
kW
NATURAL GAS
LPG
G20 - 20 mbar
28-30/37 mbar
inj. 1/100
m
3
/h
inj. 1/100
g/h
Auxiliary (small)
1
0,33
70
0,095
50
72
Semi-rapid (medium)
2
0,45
96
0,190
71
144
Rapid (double crown)
3,5
1,2
136
0,333
93
252
Burner
Ø By-pass
Tap
in 1/100
colour
of mm.
Auxiliary
28
Red/Yellow
Semi-rapid
32
Black/Green
Rapid (double-crown)
56
Black/Red
Table 1 : BY-pass diameters
Table 2 : injectors
Fig. 7
FO 1045