4.

 

Turn on the router and the mains power to the Zantiks unit. Wait a few 

minutes for the MWP unit to power on. When using the MWP version with a 

screen, text will scroll across the screen before displaying the IP address of 

the unit (which begins with the same 7 digits 192.168.1.). When using the 

MWP_vb, your IP address is included on your delivery note. If you have only 

one Zantiks unit, the IP address will be 192.168.1.101. The IP address is 

used to identify the unit on the Zantiks Control Console. 

5.

 

Using any browser-enabled device: 

 

go to your device’s network settings and connect to the wifi network 
“Zantiks” 

 

type in the network password, which is initially provided as: 

behaviour, simply 

 

go to the address bar of the web browser and type in the IP address 

for your Zantiks unit 

6.

 

Your web browser should now display the Zantiks Control Console page. 

 

 

Temperature control options for the 

MWP 

For information on temperature control options and their set up. Please refer back to the 

MWP manual. These have not changed between models.  

 

 

Assembling the Light Stand 

The light stand can incorporate a diffusing stand, and so replaces the standard 
diffusing stand that is supplied with the MWP_vb unit. The main components 

include: 

1.

 

Light stand with incorporated diffusing stand 

2.

 

LED holder (with your choice of wavelength lights) 

3.

 

Control circuit to plug directly into the MWP unit 

4.

 

Foam door (with hole for light plate) 

 

Содержание MWP

Страница 1: ...ary depending on the unit MWP_vb with come with a diffuser stand MWP_sc with come with a clear stand 5 A standard temperature control system is included with all units The peltier temperature control...

Страница 2: ...ocket of the MWP and plug it into the mains socket 3 Connect the ethernet cable at the side of the MWP unit just below the 12V power cable and plug this into any of the 4 slots available in the LAN se...

Страница 3: ...ntiks type in the network password which is initially provided as behaviour simply go to the address bar of the web browser and type in the IP address for your Zantiks unit 6 Your web browser should n...

Страница 4: ...rporates control of both the brightness of the light and the duration of the stimulus The brightness of the light is controlled by the voltage set on output4 This is the 7th connector on the 8 way out...

Страница 5: ...ating how the wires for the light stand should be connected in CN4 and CN5 of the lower board The LED holder is then connected to the control circuitry with the push connectors Push plugs connecting L...

Страница 6: ...to the MWP unit via the control circuit The LED holder can be attached to the light plate This can then be inserted into the MWP unit with the foam door to prevent any excess light entering or exitin...

Страница 7: ...LED holder attached to light stand with green LEDs...

Страница 8: ...permanently powered from the 3 way connector plugged in as in the previous photo CN4 CN4 each provides permanent 12V power a 12V power source switched by relays controlled from Zanscript and a ground...