56
Mod. NARA PL. 15-20 rev 01
IT
IT
FR
FR
ES
ES
EN
EN
Alarms
translated from the original text
IT
IT
FR
FR
ES
ES
EN
EN
Block
Message that appears if the system is
switched off in a non-manual manner during
the Switch-on phase (after Pre-loading): the
system will only switch off once operation is
steady.
Er20
Grille Sensor closed with system in Pellet
operational mode
Port
Door open
Er06
Pellet Thermostat open
Link Error
Lack of communication between keypad and
control board
4.3.5
USER MENU
To access the settings menu, press
MENU
DESCRIPTION
C o m -
b u s t i o n
manage-
ment *
Pellet po-
wer
It allows you to modify the com-
bustion power of the system in
Pellet operational mode.
Auger ca-
libration
Menu to modify the work time or
the auger speed.
Fan cali-
bration
Menu to modify the speed of the
Combustion Fan.
H e a t i n g
manage-
ment *
B o i l e r
T h e r m o -
stat
Menu to modify the Boiler Ther-
mostat value
P u f f e r
T h e r m o -
stat
Menu to modify the Puffer Ther-
mostat value. It can only be
viewed if a puffer is installed in
the system and if the menu is
enabled.
Summer -
Winter
Menu that allows for Summer -
Winter selection
Mixer Val-
ve
Menu to manage Mixer Valve
operation. It can only be viewed
if a mixer valve is installed in the
system and if the menu is ena-
bled.
R e m o t e
c o n t r o l
panel **
R o o m
Thermostat
Menu to modify the value of
the Remote control panel Room
Thermostat. (it can only be modi-
fied by technical personnel)
Enabling
It allows for the activation/de-
activation of Room Thermostat
operation. It can only be viewed
if the menu is enabled. (it can
only be modified by technical
personnel)
Chrono
Menu to select the program-
ming mode and the switch-on/
switch-off time slots
Manual load *
Menu for the manual loading of
the Auger
Reset service *
This menu allows you to reset
the system Maintenance Opera-
tion message
* Options only available on the local control panel
** Options only available on the remote control panel
4.3.6
COMBUSTION MANAGEMENT MENU
Menu to modify the system combustion parameters. It com-
prises of a number of sub-menus.
4.3.6.1
PELLET POWER
Menu that allows you to set the system combustion mana-
gement in Pellet operational mode. You can choose between
automatic and manual mode (in this case, you may also set
the power).
Combustion
Description
1 – 5
Power regulated in manual mode from 1 to 5
Auto
Power regulated automatically by the system
4.3.6.2
AUGER CALIBRATION
Menu to modify the work time or the auger speed.
There are 10 available steps from -5 to +5 with the system
being pre-set to 0.
4.3.6.3
FAN CALIBRATION
Menu to modify the speed of the combustion fan. There are
10 available steps from -5 to +5 with the system being pre-set
to 0.
4.3.7
HEATING MANAGEMENT MENU
Menu to modify the heating parameters. It comprises of a
number of sub-menus.
4.3.7.1
BOILER THERMOSTAT
Menu to modify the desired temperature of the water in the
system.
4.3.7.2
SUMMER - WINTER
Menu to modify hydraulic system operation depending on
the season. One of two symbols will appear on the display.
4.3.8
CHRONO MENU
Menu to set the system switch-on and switch-off times. This
function is only available in Pellet operational mode.
To modify the keypad chrono programming, press above the
“chrono” field on the main menu, or go to chrono in the set-
tings menu.
Modify
Time Slots
Enable
Chrono
Program-
mingType
Selection
Содержание NARA PLUS 15
Страница 2: ......
Страница 32: ......
Страница 62: ......
Страница 67: ......
Страница 68: ...Mod NARA PLUS 15 20 rev 01...