37
Mod. KERA rev 01
Installation
translated from the original text
EN
Heat radiation area
Hot air safety area
Distance from flammable or false ceilings
HOT
ZONE
Distance of the flue gas exhaust system from flammable
parts
fig. 6 minimum safety clearances for positioning product
2.5.3
FLOOR PROTECTION
In the event of heat sensitive or flammable flooring, this must
be protected (e.g., by means of steel sheets, marble slabs or
tiles). Whatever protection you choose, this must protrude at
least 300 mm at the front and 150 mm from the sides of the
stove and must withstand its weight and have a thickness of
at least 2 mm (see following fig.).
fig. 7 floor protections
Flammable object
Protection
Protection
min. 2 mm
Floor