35
Icon Alarm
Description
Possible
causes
Possible
remedies
SEE
SEr
Maintenance
When is reached a set number of
operation hours, are generated
alarms
SEE
(SEE)
stand-by
maintenance or
SEr
(SEr)
road
mode maintenance, alternating
with temperature display;
This display can be temporarily
reset by pressing any key and will
recur after switching off and the
following restart of the unit. It
will be the service center
authorized once the planned
maintenance, reset the
maintenance messages and set
later.
noL
No keyboard
communication
This symbol appears when there
is no communication between
keypad and card. If you can not
do anything with the keyboard.
You can turn off the unit only via
the ignition key of the vehicle, or
by removing the power plug.
Connection wire between
the card and keypad
defective or not properly
connected
Check the wire and the
connections on the card
and keypad
Pof
Pon
Lock/Unlock
keyboard
The abbreviation
PoF
(PoF)
indicates that the keypad lock is
active (by simultaneously
pressing of buttons
for
at least 5”)
This message is displayed for
three seconds every time the
keypad is locked you try to:
o
Set the temperature
o
Access on programming
o
Switch off the control
board
To unlock the keyboard, press
the buttons
at least 5”,
until it appears the abbreviation
Pon
(Pon)
rSt
Reset
This message is displayed for
three seconds the first time you
press a button with an alarm in
progress
5.3.4
Setting of operating parameters
As mentioned previously, you can change some settings of operation; to do this follow the instructions below:
Push
for a few seconds, it will be showed the first available parameter
To scroll to the following parameters use keys
To change a parameter, press
, set the desired value with the keys
, press again
to
confirm the value.