_________________________________________________________________5. WORKING
____________________________________________________________________________
20
CITIZEN 6 - 9/MC, CITIZEN 6+6 - 9+9/MC ELECTROMECHANICAL VERSION
for 15 seconds. When the power regulator is placed on 100, its heating
element is always on (provided the
display is on ).
5.2.11
Oven roof
and bedplate
pilot lamps
Both oven roof and bedplate pilot lamps turn on when the
display is
on and its power regulator is switching on within the regulation cycle, to
indicate that its heating element is actually on.
power regulation
position
no. secs. to switch on
no. secs. to switch off
10
3
27
20
6
24
30
9
21
40
12
18
50
15
15
60
18
12
70
21
9
80
24
6
90
27
3
100
30
0
5.3 Error display
5.3.1 Short-circuited thermocouple (vers. TERM0012)
When the thermocouple is across the line (short circuit), the
display shows “---”.
5.3.2 Disconnected thermocouple (vers. TERM0012)
When the thermocouple is disconnected or interrupted, the
display shows
“EEE”.
The same code of error appears if the baking chamber temperature
exceeds the maximum temperature that can be selected.
5.3.3 Disconnected thermocouple (vers. TERM0060)
When the thermocouple is disconnected or interrupted, the
display shows “
PR1
”.
The same code of error appears if the baking chamber temperature
exceeds the maximum temperature that can be selected.