6
For guarantees please refer to the respective terms and
conditions of supply for your country.
The installation, electrical connection and first
operation of this appliance should be carried out by
a qualified installer.
The company does not accept liability for failure of any
good supplied which have not been installed and operated in
accordance with the manufacturer’s instructions.
2.1 Important information
- Currently-applicable data on the supply rating plate.
- Install the unit flush with the wall.
- Piped supplementary heating is not permissible.
- Water installation material. Cold water : pipe-steel or copper.
Hot water : pipe-copper.
- Electrical connection to permanently installed leads via
circuit breaker.
- Fitting for open-outlet units are not permitted.
- Safety valves are not required.
Additional Safety.
If for any reason, excessive heating occurs the manual reset
thermal cut-out will cut off the power permanently
* Customer must call for service from a qualified technician.
2.2 Putting the water heater into operation
1. Turn on circuit breaker to bring electrical power to the unit.
2. Adjust the water temperature to the desired level using the
knob on the front cover of the unit.
3. Turn on hot water and wait twenty seconds until
temperature has stabilized.
4. Check the water temperature with your hand and make sure
that it does not feel too hot. Reduce if necessary.
5. Explain to the user how the unit works and familiarize him
or her with its use.
Advise the user about possible hazards. Hand over these
instructions, to be kept for future reference.
Warning:
Open hot water faucet for a few minutes until water
flow is continuous and all air is purged from water pipes. The
unit’s plastic cover must be installed before the circuit breaker
is turned on.
Normal maintenance
The Mini Multipoint water heater is designed for a very long
service life. Actual life expectancy will vary with water quality
and use. The unit itself does not require any regular mainte-
nance. However, to ensure consistent water flow, it is recom-
mended to periodically remove scale and dirt that may build
up at the aerator of the faucet or in the shower head.
2.3 Care and Maintenance
All that is needed for cleaning the housing is a damp cloth. Do
not use any abrasive cleaning agents or agents containing
solvents.
Maintenance work may only be carried out by a
qualified technician.
2. Operating instructions
for the user and the qualitified installer
3. Guarantee
Fault
No hot water
Water not hot enough
Cause
- circuit breaker off
- safety thermal cut-out tripped
- water flow too high
- voltage too low
Rectification
- turn circuit breaker on
- reset thermal cut-out
- reduce water flow rate
- supply correct voltage to unit
4. Fault elimination for the user