Cabinet width
560 mm
Cabinet depth
550 (550) mm
Height of the front of the
appliance
598 mm
Height of the back of the
appliance
579 mm
Width of the front of the
appliance
594 mm
Width of the back of the
appliance
558 mm
Depth of the appliance
561 mm
Built in depth of the appli-
ance
540 mm
Depth with open door
1007 mm
Ventilation opening mini-
mum size. Opening placed
on the bottom rear side
560x20 mm
Mounting screws
4x25 mm
Before you install the appliance, fit it with the applicable
hob from the table.
Type
Maximum power
KEV6046XXK
7400 W
KAV6041XXK
6500 W
KEV6043FBB
7600 W
KEV6041FBB
6000 W
Electrical connection
Warning! Risk of fire and electric shock.
• All electrical connections should be made by a
qualified electrician.
• The appliance must be earthed.
• Make sure that the parameters on the rating plate
are compatible with the electrical ratings of the
mains power supply.
• Always use a correctly installed shockproof socket.
• Do not use multi-plug adapters and extension
cables.
• Make sure not to cause damage to the mains plug
and to the mains cable. Should the mains cable
need to be replaced, this must be carried out by our
Authorised Service Centre.
• Do not let mains cables touch or come near the
appliance door or the niche below the appliance,
especially when it operates or the door is hot.
• The shock protection of live and insulated parts
must be fastened in such a way that it cannot be
removed without tools.
• Connect the mains plug to the mains socket only at
the end of the installation. Make sure that there is
access to the mains plug after the installation.
• If the mains socket is loose, do not connect the
mains plug.
• Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug.
• Use only correct isolation devices: line protecting
cut-outs, fuses (screw type fuses removed from the
holder), earth leakage trips and contactors.
• The electrical installation must have an isolation
device which lets you disconnect the appliance from
the mains at all poles. The isolation device must
have a contact opening width of minimum 3 mm.
• This appliance is supplied without a main plug and a
main cable.
• The hob connection socket is at the top of the oven
cabinet. The hob has connection leads for the
cooking zones and the ground cable. The leads
have plug-in connectors. Plug the connectors into
the correct oven socket to connect the hob to the
oven. The design of the plugs and sockets prevents
incorrect connections.
If the mains voltage is different, rearrange the jumpers
on the terminal board (refer to the connection diagram
below). Connect the ground cable to the terminal. After
you connect the supply cable to the terminal board,
attach it with a junction clamp.
Connecting to terminal board
The appliance has a six-pole terminal board. The
jumpers (bridges) are set for operation on a 400 V
three-phase with a neutral wire.
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
1
2
3
4
5
22
Содержание KOU20723XK
Страница 1: ...KOU20723XK Benutzerin formation Backofen User Manual Oven Notice d utili sation Four...
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ...www electrolux com shop 867368559 A 282021...