Restaurant Equipment & Supplies
Safety
Installation
CAUTION
• The cooler must be grounded correctly,never with a heating pipe and coal gas pipe.
• In case of damage to electrical cord and plug,please contact after sale service and never do it yourself.
• When unplugging unit,please grasp by the plug,not the cord.
• If the voltage is unstable,please select a suitable automatic voltage regulator.
• If the power cuts off,you should wait for at least 5 minutes before turning on the unit again to avoid damage
to the compressor.
• Never store any flammable,explosive or corrosive liquid or gas in or near the cooler.
PROPER DISPOSAL OF EQUIPMENT; DANGER! RISK OF CHILD ENTRAPMENT
Child entrapment and suffocation are not problems of the past. Junked or abandoned refrigerators are still
dangerous, even if they will sit for “just a few days.” If you are getting rid of an old refrigerator, please follow the
below instructions to help prevent a terrible accident.
• Remove the doors.
• Leave shelves in place to prevent children from easily climbing inside.
REFRIGERANT DISPOSAL
Your old refrigerator may have a cooling system that used “ozone depleting” chemicals. If you are throwing
away your old refrigerator, be sure the refrigerant is removed for proper disposal by a qualified service
technician. If you intentionally release any refrigerants you can be subject to fines and imprisonment under the
provisions of the environmental regulations.
Tools required: Phillips screw driver.
• Use a Phillips screw driver to remove the four (4) screws from the L-bracket connecting the unit to the
wood skid. Then remove the L-bracket from the unit.
• Remove skid by unscrewing all base rail anchor brackets. Place skid to the side.
• Carefully upright cabinet.
When lifting unit do not use the counter top as a lifting point. Also remember to leave cabinet upright
for 24-hours before plugging into power source.
• Set unit in its final location. Make sure there is adequate ventilation in this location. Under extreme heat
conditions (+100°F / +38°C) an exhaust fan may be necessary.
• Proper leveling of the unit is critical to operating success (for non-mobile models). Effective condensate
removal and door operation will be affected by leveling.
• The cooler should be leveled front to back and side to side with a level.
Содержание 51000-081
Страница 24: ...Restaurant Equipment Supplies Item 51000 081 Item 51000 082 Item 51000 084 Item 51000 085 Parts Breakdown ...
Страница 27: ...Restaurant Equipment Supplies Parts Breakdown Item 51000 083 Item 51000 086 ...
Страница 29: ...Restaurant Equipment Supplies Parts Breakdown Item 51000 087 ...
Страница 31: ...Restaurant Equipment Supplies Parts Breakdown Item 51000 088 ...
Страница 33: ...Restaurant Equipment Supplies Parts Breakdown Item 51000 089 ...
Страница 35: ...Restaurant Equipment Supplies Electrical Schematics Item 51000 081 Item 51000 084 Item 51000 087 ...
Страница 36: ...Restaurant Equipment Supplies Item 51000 082 Item 51000 085 Item 51000 088 Electrical Schematics ...
Страница 37: ...Restaurant Equipment Supplies Electrical Schematics Item 51000 083 Item 51000 086 Item 51000 089 ...
Страница 38: ...Restaurant Equipment Supplies ...