Safety Relay MINOS SD1E
EN
Note:
Config-Switches are set as follows:
S1
: Disabled /
S2
: Automatic
(see chapter 7. “Function”)
Application example 5:
SD1E for two-channel monitoring of an
OSSD-Output, e.g. light curtain/grid and
automatic start up to PL e / SIL 3 (cross
circuit monitoring by OSSD-Output)
Fig. 7
Monitoring of an OSSD-Output, e.g. light
curtain / light grid with auto-start
Legend for all application examples:
E-Stop: Emergency stop button
Start: Start button
K
A
/K
B
: Positively driven contactors;
Monitoring via feedback circuit
PL and SIL: According to EN ISO 13849-1
and IEC 62061 / IEC 61508.
Specified safety level, considering a fault
exclusion in the wiring between SD1E and the
connected contactors K
A
and
KB
. See details
in chapter 15 "Wiring / Applications - Safe
relay contact
”