background image

RZB-05 WIRELESS CONTROL SET  

- UNIVERSAL 

 

MANUAL INSTRUCTION

ZAMEL 

Sp. z o.o.

ul. Zielona 27, 43-200 Pszczyna, Poland

tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04

www.zamelcet.com

, e-mail: [email protected]

VER. 003_20.05.2011

APPEARANCE

FEATURES

TECHNICAL DATA

● complete set of wireless control (2–chan-

nel remote controller P-257/2 and 1-chan-

nel radio flush receiver ROP-01),

● lighting,  heating  operation  control,  other 

receivers control,

● easy installation in an electric-light fitting 

or in Ø60 mm junction box,

● possibility to use the second remote con-

troller’s push-button to control other EXTA 

FREE receivers,

● 5 operation modes: switching on, switch-

ing off, monostable mode, bistable mode, 

time mode  (switch off delay),

● wide operation range (up to 180 m),

● low  current  consumption,  possibility  of 

constant operation,

● possibility  of  increasing  operation  range 

by means of RTN-01 retransmitter.

P-257/2

ROP-01

Input (supply) terminals:

-

L, N

Input rated voltage:

3 V DC (CR2032 battery)

230 V AC

Battery life:

3 ÷ 5 years

-

Input voltage tolerance:

-

-15 ÷ +10 %

Nominal frequency:

-

50 / 60 Hz

Nominal power consumption:

-

0,29 W

Number of operation modes:

-

5

Number of channels

2

1

Transmission:

radio 868,32 MHz

Coding way:

unidirectional

Coding:

addressing transmission

Maximum number of remote controls:

-

32

Range:

up to 180 m in the open area

up to 180 m in the open area

Time adjustment:

-

1 sec÷ 18 hours (every 1 sec)

Optic signalling of transmitter’s operation:

LED red diode

Relay output terminals:

-

12, 11, 14

Relay contact parameters:

-

1NO/NC 5A / 250V AC AC1 1250 VA

Number of terminal clamps:

-

5

Section of connecting cables:

-

up to 2,5 mm

2

Ambient temperature range:

-10 ÷ +55 

o

C

Operating position:

free

Mounting:

-

installation cable box Ø60 mm

Casing protection degree:

IP20 (EN 60529)

Protection level:

III

II

Overvoltage category:

-

II

Pollution degree:

2

Surge voltage:

-

1 kV (PEN 61000-4-5)

Dimensions:

74 x 33 x 11,5 mm

47,5 x 47,5 x 20 mm

Weight

0,020 kg

0,043 kg

Reference standard:

ETSI EN 300 220-1

ETSI EN 300 220-2

EN 60669, EN 60950

EN 61000

Optic signalling 
of receiver’s operation
Programming push-button

Relay output terminals
(12, 11, 14)

Input (supply) terminals (L, N)

Optic signalling of transmitter’s operation

Push-buttons

DESCRIPTION

Radio flush receivers are used both as 

elements in mounting in flush and surface 
installation cable boxes and as an actuator 
built  directly  in  lighting  fitting  casings  and 
other  receivers).  ROP-01  enables  op-
eration in 5 different modes (switching on, 
switching  off,  monostable  mode,  bistable 
mode, time mode.

The  device  is  designed  for 

single-phase  installation  and 

must be installed in accord-

ance  with  standards  valid  in  

a  particular  country.  The  de-

vice  should  be  connected 

according  to  the  details  in-

cluded  in  this  operating  manual.  Installation, 

connection and control should be carried out by  

a qualified electrician staff, who act in accord-

ance  with  the  service  manual  and  the  device 

functions. 

In case of casing dismantling an electric shock 

may occur, and the guarantee is lost then. Be-

fore  installation make sure the connection ca-

bles are not under voltage. The cruciform head 

screwdriver 3,5 mm should be used to instal the 

device.  Improper  transport,  storage,  and  use  

of  the  device  influence  its  wrong  functioning.  

It  is  not  advisable  to  instal  the  device  in  the 

following cases:  if any device part is missing  

or the device is damaged or deformed. In case 

of  improper functioning of the device contact 

the producer.

CAUTION!

The symbol means selective 

collecting of electrical and electronic 

equipment.  

It is forbidden to put the used 

equipment together with other waste.

WARRANTY CARD

There is 24 months guarantee on the product

1.  ZAMEL provides a two-year warranty for its products. 

2.  The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances  

b) defects resulting from incorrect installation or operation of ZAMEL products; c) defects resulting from any changes made by CUS-

TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting 

from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device 

in the moment of sale (if they appear); 

3.  All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.; 

4.  ZAMEL will review complaints in accordance with existing regulations.; 

5.  The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. 

6.  Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy 

between the goods and the contract.

Salesman stamp and signature, date of sale

CONNECTION

APPLICATION

CAPACITY

750W

250W

500W

375W

ROP-01 MOUNTING

1.  Disconnect power supply by the phase 

fuse,  the  circuit-breaker  or  the  switch-

disconnector  combined  to  the  proper 

circuit.

2. Check if there is no voltage on connec-

tion cables by means of a special meas-

ure equipment.

3. Connect  the cables with the terminals in 

accordance with the installing diagram.

4. Install ROP-01 device in installation ca-

ble box.  

5. Switch on the power supply from the mains.

P-257/2 OPERATION

By  pressing  the  P-257/2  push-button, 

the remote controller sends a signal with 

868,32  MHz  frequency  which  controls 

EXTA FREE receivers. 

Device program-

ming procedure (adding a transmitter 

to a receiver’s memory) is described in 

particular EXTA FREE manual instruc-

tions.

 The device range (up to 250 m de-

pending on a receiver) can be increased 

by means of a retransmitter or few RTN-01 

retransmitters.

BATTERY CHANGE P-257/2

Battery discharge status is signalled 

by several LED red diode flashes dur-

ing transmission time.

1. Remove the button (mounting - point 1).

2. By means of a screwdriver lever up the 

printed-circuit board releasing the bot-

tom latch and remove it from the base.

3. Remove the battery from the latch.

4. Mount  a  new  battery. 

Watch battery 

polarisation marked on the latch. 

Wrong battery mounting may cause 

device damage.

5. Put  the  removed  printed-circuit  board 

back in the base.

6. Put back the button.

CAUTION:

While changing the battery, it is sug-

gested to press any of the buttons for 

about 5 seconds before putting it into 

a latch. Next press transmission button 

several times to check its operation.  

If the transmitter does not work proper-

ly repeat the battery change procedure.

2-channel remote controller P-257/2 

operates radio flush receiver  

ROP-01 and remote control socket 

RWG-01. RNK-02 button radio 

transmitter and RWL-01 radio 

lighting switch are also EXTA FREE 

system devices.

The ZAMEL company 

devices which are 

characterised with this sign 

can cooperate 

with each other.

Отзывы: