OPERATION, MOUNTING RNK-02
By pressing the button, the transmitter sends a signal with 868,32 MHz frequency
which controls EXTA FREE receivers.
Device programming procedure (adding
a transmitter to a receiver’s memory) is described in particular EXTA FREE
manual instructions. The device range (up to 250 m depending on a receiver)
can be increased by means of a retransmitter or few RTN-01 retransmitters.
The device can be mounted in any place by means of double-sided adhesive tape or
wall plugs 5 x (3 x 30) mm.
Mounting by means of wall plugs:
Remove the button - to do it press the button on one side, and on the other side put
a screwdriver into a slot and lift up the button (Fig. 1)
Find a place on the wall to mount the transmitter, make two holes corresponding
mounting holes from the transmitter’s base.
Set wall plugs in the holes.
Fix the base by means of screwing screws into wall plugs.
Place the button again.
BATTERY CHANGE
Battery discharge status is signalled by several LED red diode flashes during
transmission time.
Remove the button (Fig. 1).
By means of a screwdriver lever up the printedcircuit board releasing the bottom
latch (Fig. 2), and remove it from the base.
Remove the battery from the latch (Fig. 3).
Mount a new battery. Watch battery polarisation marked on the latch. Wrong bat-
tery mounting may cause device damage.
Put the removed printed-circuit board back in the base.
Put the button back.
CAUTION: While changing the battery, it is suggested to press any of the but-
tons for about 5 seconds before putting it into a latch. Next press transmission
button several times to check its operation. If the transmitter does not work
properly repeat the battery change procedure.
MOUNTING SRP-02
CONNECTION
Disconnect power supply by the phase fuse, the circuit-breaker or the switch-discon-
nector combined to the proper circuit.
Check if there is no voltage on connection cables by means of a special measure
equipment.
Connect the cables with the terminals in accordance with the installing diagram.
Install SRP-02 device in the junction box.
Switch on the power supply from the mains.
LOCAL
LOCAL
2
OPERATION SRP-02
Pressing shortly the programmed push-button in local mode (<2 sec.) or roller blind
switch (optional) causes the roller blind moves. Another short pressing of the same
push-button or the switch causes the roller blind stops at a required level. Pressing
the push-button or the switch longer (>2 sec.) causes comfort mode activates (the
roller blind moves in a required direction and stops according to the adjusted time).
Pressing shortly transmitter’s push-button (programmed in the central mode) causes
complete opening or closing of the roller blind.
RADIO TRANSMITTERS PROGRAMMING
LOCAL mode:
Press PROG push-button of SRP-02 device for a longer time until LED red diode
switches on (constant signal). Next release PROG push-button.
Press and release transmitter’s first push-button (movement ). LED red diode
switches on (first signal pulsates, next the signal is constant).
Press and release the second transmitter’s push-button (movement ). LED red
diode switches on (signal pulsates) and then switches off - THE TRANSMITTER IS
ADDED.
CENTRAL mode:
Press PROG push-button of SRP-02 device for a longer time until LED red diode
switches on (constant signal). Next release PROG push-button. Wait (for about
5 seconds) till LED red diode switches on (first signal pulsates, next the signal is
constant).
Press and release transmitter’s first push-button (movement ). LED red diode
switches on (first signal pulsates, next the signal is constant).
Press and release the second transmitter’s push-button (movement ). LED red
diode switches on (the signal pulsates) and next it switches off - THE TRANSMITTER
IS ADDED.
An exemplary programming procedure with P-257/4 remote control. The procedure for
the rest of radio EXTA FREE transmitters is analogous with reservation that 2-channel
transmitters can be programmed only in one mode - local or central.
CAUTION: If push-button changes are required for local and central control (in
a 4-channel transmitter) the programming procedure should be for two modes
separately (first local control push-buttons, then central control push-buttons).
In case of a 2- channel transmitter the change from local control to central con-
trol should start with controller’s memory deletion and only then transmitter’s
programming procedure for central mode can start. One transmitter can be add-
ed during one programming cycle. Full memory is signalled with pulsating LED
red diode.
Fig. 1
Fig. 2
Fig. 3