COOPERATION AND OPERATING RANGE
* 1-channel transmitters do not cooperate with roller blind controllers
CAUTION: The given range concerns open area - an ideal condition without any
natural or artificial obstacles. If there are some obstacles between a transmitter
and a receiver, it is advisable to decrease the range according to: wood and pla-
ster: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %,
metal: from 90 to 100%, glass: from 10 to 20 %, Over- and underground medium
and high electrical power lines, radio and television transmitters, GSM transmit-
ters set close to a device system have also a negative influence on the range.
Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01
RNK-02
180 m
200 m
200 m
200 m
200 m
250 m
180 m
250 m
250 m
180 m
250 m
RNK-04
180 m
200 m
200 m
200 m
200 m
250 m
180 m
250 m
250 m
180 m
250 m
P-256/8
230 m
250 m
250 m
250 m
250 m
300 m
200 m
300 m
300 m
230 m
300 m
P-257/4 (2)
180 m
200 m
200 m
200 m
200 m
250 m
180 m
250 m
250 m
180 m
250 m
RNM-10
230 m
250 m
250 m
250 m
250 m
300 m
200 m
300 m
300 m
230 m
300 m
RNP-01
160 m
180 m
180 m
180 m
180 m
200 m
160 m
200 m
200 m
160 m
200 m
RNP-02
160 m
180 m
180 m
180 m
180 m
200 m
160 m
200 m
200 m
160 m
200 m
RNL-01
160 m
180 m
180 m
lack*
lack*
200 m
160 m
200 m
200 m
160 m
200 m
RTN-01
200 m
200 m
200 m
200 m
200 m
250 m
200 m
250 m
250 m
200 m
250 m
RCR-01
160 m
180 m
180 m
lack*
lack*
200 m
160 m
200 m
200 m
160 m
200 m
RTI-01
160 m
180 m
180 m
180 m
180 m
200 m
160 m
200 m
200 m
160 m
200 m
RXM-01
230 m
250 m
250 m
250 m
250 m
300 m
200 m
300 m
300 m
230 m
300 m
Press PROG push-button of SRP-02 device for a longer time. After 5 seconds
LED red diode switches on (signal pulsates) and then it switches off. Release the
push-button in SRP-02 - MEMORY IS DELETED.
RADIO TRANSMITTERS DELETION
COMFORT MODE TIME PROGRAMMING
Open the roller blind completely.
Press PROG push-button of SRP-02 device for a longer time until LED red diode
switches on (constant signal). Next release PROG push-button. Wait (for about
5 seconds) till LED red diode switches on (first signal pulsates, next the signal is
constant).
Wait again (for about 5 seconds) till LED red diode switches on (first signal pulsates,
next the signal is constant).
Press PROG push-button of SRP-02 device, next release PROG push-button - the
roller blind moves automatically.
If the roller blind is in a required comfort position - press PROG push-button and
release it - the roller blind stops - ROLLER BLIND MOVEMENT TIME IS ADDED.
WIRELESS CONTROL SET - ROLLER BLINDS CONTROL
RZB-03
TECHNICAL DATA
RNK-02
SRP-02
Input (supply) terminals:
-
L, N
Input rated voltage:
3 V (battery CR2032)
230 V~
Battery life:
3 ÷ 5 years
-
Input voltage tolerance:
-
+10 ÷ -15 %
Nominal frequency:
-
50 / 60 Hz
Nominal power consumption:
-
0,4 W („stand-by” mode)
0,7 W (roller blind movement)
Transmission:
radio 868,32 MHz
Transmission way:
unidirectional
Coding:
addressing transmission
Maximum number of transmitters:
-
32
Range:
up to 250 m in the open air
Maximum time of roller blind
movement:
-
120 s
Comfort mode time adjustment:
-
1 ÷ 120 sec (every 0,1 sec)
Optical signalling:
LED red diode
Local control terminals:
-
LOCAL (up), (down)
Roller blind motor power supply
terminals:
-
(up), (down)
Relay contact parameters:
-
2NO 5A / 250V AC3 1250 VA
Number of terminal clamps:
-
6
Section of connecting cables:
-
up to 2,5 mm
2
Ambient temperature range:
-10 ÷ +55
o
C
Operating position:
free
Casing mounting:
wall plugs, double-sided
adhesive tape
installation cable box Ø60 mm
Casing protection degree:
IP20 (PN-EN 60529)
Protection level:
III
II
Overvoltage category:
-
II
Pollution degree:
2
Surge voltage:
-
1 kV (PN-EN 61000-4-5)
Dimensions:
90 x 80 x 11,5 mm
47,5 x 47,5 x 20 mm
Weight:
0,038 kg
0,039 kg
Reference standard:
PN-ETSI EN 300 220-1
PN-ETSI EN 300 220-2
PN-EN 60669, PN-EN 60950,
PN-EN 61000