background image

RZB-03 WIRELESS CONTROL SET 

– ROLLER BLINDS CONTROL

 

MANUAL INSTRUCTION

ZAMEL 

Sp. z o.o.

ul. Zielona 27, 43-200 Pszczyna, Poland

tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04

www.zamelcet.com

, e-mail: [email protected]

VER. 003_20.05.2011

APPEARANCE

The device is designed for 

single-phase installation and 

must be installed in accord-

ance with standards valid in  

a particular country. The de-

vice should be connected ac-

cording to the details included 

in this operating manual. Installation, connection 

and control should be carried out by a qualified 

electrician staff, who act in accordance with the 

service manual and the device functions. 

In case of casing dismantling an electric shock 

may occur, and the guarantee is lost then. Before  

installation make sure the connection cables are 

not under voltage. The cruciform head screwdriv-

er 3,5 mm should be used to instal the device. Im-

proper transport, storage, and use of the device 

influence its wrong functioning. It is not advisable 

to instal the device in the following cases:  if any 

device part is missing or the device is damaged 

or deformed. In case of  improper functioning of 

the device contact the producer.

CAutioN!

FEAtuRES

tECHNiCAL DAtA

DESCRiPtioN

●  Complete  set  of  wireless  control  

(2–channel button radio transmitter 

RNK-02 and radio roller blinds controller 

SRP-02), 

●  used  in  wired  and  wireless  control  of 

roller blind, sunblind and gate drives, 

(electric motors of 230V AC),

●  wired local control inputs,

●  easily installed in Ø60 mm junction box,

●  energy-saving device, possibility of con-

stant work,

●  two comfort modes - upper and bottom 

(memory of roller blind height level),

●  possibility of cooperation with any roler 

blind switch (which is not equipped in 

backlight elements)

SRP-02 controller is used to control 

roller blind drives with 230V AC motor with 

a limit switch. The device realises roller 

blinds local and central control functions 

and it has the possibility of comfort mode 

adjustment.  Comfort  modes  are  used  to 

adjust  roller  blinds  position  (height  level) 

and to memorise the height level. Central 

mode is used in case of a totally closed 

or opened roller blind or a group of roller 

blinds with different position level.

RNK-02

SRP-02

Input (supply) terminals:

-

L, N

Input rated voltage:

3 V DC (CR2032 battery)

230 V AC

Battery life:

3 ÷ 5 years

-

Input voltage tolerance:

-

+10 ÷ -15 %

Nominal frequency:

-

50 / 60 Hz

Nominal power consumption:

-

0,4 W („stand-by” mode) / 0,7 W (roller blind movement)

Transmission:

radio 868,32 MHz

Coding way:

unidirectional

Coding:

addressing transmission

Maximum number of remote controls:

-

32

Range:

up to 250 m in the open area

Maximum movement time of roller blind: 

-

120 sec

Maximum time of roller blind movement:

-

1 ÷ 120 sec (every 0,1 sec)

Optic signalling of transmitter’s operation:

LED red diode

Local control terminals:

-

LOCAL   (up),   (down)

Motor power supply terminals:

-

 (up),   (down)

Relay contact parameters:

-

2NO 5A/250V AC AC3 1250 VA

Number of terminal clamps:

-

6

Section of connecting cables:

-

up to 2,5 mm

2

Ambient temperature range:

-10 ÷ +55 

o

C

Operating position:

free

Casing mounting: wall plugs, double-sided adhesive tape

installation cable box Ø60 mm

Casing protection degree:

IP20 (EN 60529)

Protection level:

III

II

Overvoltage category:

-

II

Pollution degree:

2

Surge voltage:

-

1 kV (EN 61000-4-5)

Dimensions:

90 x 80 x 11,5 mm

47,5 x 47,5 x 20 mm

Weight:

0,038 kg

0,039 kg

Reference standard:

ETSI EN 300 220-1

ETSI EN 300 220-2

EN 60669, EN 60950, 

EN 61000

The symbol means selective 

collecting of electrical and electronic 

equipment.  

It is forbidden to put the used 

equipment together with other waste

Optic signalling of receiver’s operation
Programming push-button

Local wired control terminals 
(upward movement  , downward movement  )

Roller blind motor terminals
(upward movement  , downward movement  )
Input (supply) terminals (L, N)

Optic signalling 
of transmitter’s operation

Push-button

CoNNECtioN

APPLiCAtioN

LOCAL 

LOCAL 

SRP-02 MouNtiNG

1. Disconnect power supply by the phase fuse, 

the circuit-breaker  or the switch-disconnector 

combined to the proper circuit.

2. Check if there is no voltage on connec-

tion cables by means of a special measure 

equipment.

3. Connect the cables with the terminals in ac-

cordance with the installing diagram.

4. Install SRP-02 device in installation cable box.

5. Switch on the power supply from the mains.

RNK-02 FuNCtioNiNG, MouNtiNG

By pressing the button, the transmitter sends a 

signal with 868,32 MHz frequency which controls 

EXTA FREE receivers. 

Device programming 

procedure (adding a transmitter to a receiv-

er’s memory) is described in particular EXtA 

FREE manual instructions.

 The device range 

(up to 250 m depending on a receiver) can be in-

creased by means of a retransmitter or few RTN-

01 retransmitters. The device can be mounted in 

any place by means of double-sided adhesive 

tape or two wall plugs (5x(3x30) mm.

Mounting by means of wall plugs:

1. Remove the button - to do it press the button 

on one side, and on the other side put a screw-

driver into a slot and lift up the button.

2. Find a place on the wall to mount the transmit-

ter, make two holes corresponding mounting 

holes from the transmitter’s base.

3. Set wall plugs in the holes.

4. Fix the base by means of screwing screws into 

wall plugs.

5. Place the button again.

BAttERY CHANGE

Battery discharge status is signalled by sev-

eral LED red diode flashes during transmis-

sion time.

1. Remove the button (mounting - point 1).

2. By means of a screwdriver lever up the printed-

circuit board releasing the bottom latch and re-

move it from the base.

3. Remove the battery from the latch.

4. Mount a new battery. 

Watch battery polari-

sation marked on the latch. Wrong battery 

mounting may cause device damage.

5. Put the removed printed-circuit board back in 

the base.

6. Put back the button.

CAutioN: 

While changing the battery, it is suggested to 

press any of the buttons for about 5 seconds 

before putting it into a latch. Next press trans-

mission button several times to check its op-

eration. if the transmitter does not work prop-

erly repeat the battery change procedure.

WARRANtY CARD

There is 24 months guarantee on the product

1.  ZAMEL provides a two-year warranty for its products. 

2.  The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances  

b) defects resulting from incorrect installation or operation of ZAMEL products; c) defects resulting from any changes made by CUS-

TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting 

from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device 

in the moment of sale (if they appear); 

3.  All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.; 

4.  ZAMEL will review complaints in accordance with existing regulations.; 

5.  The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. 

6.  Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy 

between the goods and the contract.

Salesman stamp and signature, date of sale

CAutioN: 

Local switches connection (LoCAL) is optional.

Radio flush dimmer RNK-02 operating roller 

blind controller SRP-02 (roller blind opening / 

closing). The above mentioned transmitter can 

be added to any number of receivers.

The ZAMEL company 

devices which are 

characterised with this sign 

can cooperate 

with each other.

Отзывы: