RADio tRANSMittERS PRoGRAMMiNG
RADio tRANSMittERS DELEtioN
SRP-02 oPERAtioN
Pressing shortly the programmed push-button in local mode (<2 sec.) or roller blind switch (optional) causes the roller blind moves. Another
short pressing of the same push-button or the switch causes the roller blind stops at a required level. Pressing the push-button or the switch
longer (>2 sec.) causes comfort mode activates (the roller blind moves in required direction and stops according to the adjusted time).
Pressing shortly transmitter’s push-button (programmed in central mode) causes complete opening or closing the roller blind.
CoMFoRt MoDE tiME PRoGRAMMiNG
CooPERAtioN AND oPERAtiNG RANGE
Symbol
RoP-01 RoP-02 RoB-01 SRP-02 SRP-03 RWG-01 RWL-01 RoM-01 RoM-10 RDP-01 RtN-01
RNK-02
180 m
200 m
200 m
200 m
200 m
250 m
180 m
250 m
250 m
180 m
250 m
RNK-04
180 m
200 m
200 m
200 m
200 m
250 m
180 m
250 m
250 m
180 m
250 m
P-256/8
230 m
250 m
250 m
250 m
250 m
300 m
200 m
300 m
300 m
230 m
300 m
P-257/4 (2)
180 m
200 m
200 m
200 m
200 m
250 m
180 m
250 m
250 m
180 m
250 m
RNM-10
230 m
250 m
250 m
250 m
250 m
300 m
200 m
300 m
300 m
230 m
300 m
RNP-01
160 m
180 m
180 m
180 m
180 m
200 m
160 m
200 m
200 m
160 m
200 m
RNP-02
160 m
180 m
180 m
180 m
180 m
200 m
160 m
200 m
200 m
160 m
200 m
RNL-01
160 m
180 m
180 m
lack*
lack*
200 m
160 m
200 m
200 m
160 m
200 m
RtN-01
200 m
200 m
200 m
200 m
200 m
250 m
200 m
250 m
250 m
200 m
250 m
RCR-01
160 m
180 m
180 m
lack*
lack*
200 m
160 m
200 m
200 m
160 m
200 m
Rti-01
160 m
180 m
180 m
180 m
180 m
200 m
160 m
200 m
200 m
160 m
200 m
RXM-01
230 m
250 m
250 m
250 m
250 m
300 m
200 m
300 m
300 m
230 m
300 m
* -1-channel transmitters do not cooperate with roller blind controllers.
CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles
between a transmitter and a receiver, it is advisable to decrease the range according to: wood and plaster: from 5 to 20 %, bricks: from 10 to 40 %,
reinforced concrete: from 40 to 80 %, metal: from 90 to 100%, glass: from 10 to 20 %, over- and underground medium and high electrical power lines,
radio and television transmitters, GSM transmitters set close to a device system have also a negative influence on the range.
tRANSMittERS
RECEiVERS
RNK-02
2–channel button
radio transmitter
RNL-01
Radio
foot transmitter
RoP-01
1-channel
radio receiver
RWL-01
Radio lighting
switch
RNK-04
4-channel button
radio transmitter
Rti-01
IR/EXTA FREE
transceiver
RoP-02
2-channel
radio receiver
RWG-01
Remote control
socket
P-256/8
8-channel
remote controller
RNM-10
4-channel radio
modular transmitter
RDP-01
1-channel
radio dimmer
SRP-02
Radio roller blinds
controller
P-257/4
4-channel
remote controller
RNP-01
4-channel
radio transmitter
RoB-01/12-24V
Radio
gate controller
SRP-03
Central radio roller
blinds controller
P-257/2
2-channel
remote controller
RNP-02
4-channel
radio transmitter
RoM-01
1-channel radio
modular receiver
RoM-10
2-channel
radio modular receiver
RCR-01
Radio
motion sensor
RXM-01
Translator
RS-485/EXTA FREE
ACCESSoRiES
ANt-01
External antenna
RtN-01
Retransmitter
RANGE LoSS CoNCERNiNG RADio SiGNALS GoiNG tHRouGH oBStACLES
bricks: from 10 to 40 %, wood and plaster: from 5 to 20 %,
reinforced concrete: from 40 to 80 %, metal: from 90 to 100%, glass: from 10 to 20 %
LoCAL
mode:
CENtRAL
mode:
Open the roller
blind completely.
If the roller blind is in a required
comfort position - press PROG push-
button and release it - the roller blind
stops - ROLLER BLIND MOVEMENT
TIME IS ADDED.
Press PROG push-button of SRP-02 device,
next release PROG push-button - the roller
blind moves automatically.
An exemplary programming procedure with P-257/4 remote control. The procedure for the rest of radio EXTA FREE transmitters is analogous
with reservation that 2-channel transmitters can be programmed only in one mode - local or central.
CAutioN: if push-button changes are required for local and central control (in 4-channel transmitter) the programming procedure
should be for two modes separately (first local control push-buttons, then central control push-buttons). In case of 2- channel
transmitter the change from local control to central control should start with controller’s memory deletion and only then transmitte-
r’s programming procedure for central mode can start. one transmitter can be added during one programming cycle. Full memory
is signalled with pulsating LED red diode.
Time programming example for upper comfort mode. In order to programme time for bottom comfort mode, it is necessary to close the roller blind completely
before programming procedure starts. Maximum time is 120 seconds.
Press PROG push-button of SRP-02 device
for a longer time until LED red diode switches on
(constant signal). Next release PROG push-button.
Press PROG push-button of SRP-02 device
for a longer time until LED red diode switches on
(constant signal). Next release PROG push-button.
Wait (for about 5 seconds) till LED red diode switches
on (first signal pulsates, next the signal is constant).
Press PROG push-button of SRP-02 device for a longer time until
LED red diode switches on (constant signal). Next release PROG
push-button. Wait (for about 5 seconds) till LED red diode switches
on (first signal pulsates, next the signal is constant).
Wait again (for about 5 seconds) till
LED red diode switches on (first signal
pulsates, next the signal is constant).
Press and release transmitter’s first
push-button (movement ). LED red
diode switches on (first signal pulsates,
next the signal is constant).
Press and release transmitter’s first
push-button (movement ...). LED red
diode switches on (first signal pulsates,
next the signal is constant).
Press and release the second
transmitter’s push-button
(movement ). LED red diode switches on
(signal pulsates) and then switches off -
THE TRANSMITTER IS ADDED.
Press and release the second
transmitter’s push-button (movement ...).
LED red diode switches on (the signal
pulsates) and next it switches off -
THE TRANSMITTER IS ADDED.
Press PROG push-button of SRP-02
device for a longer time.
After 5 seconds LED red diode switches on
(signal pulsates) and then it switches off.
Release the push-button in SRP-02 -
MEMORY IS DELETED.