background image

2-CHANNEL RADIO FLUSH RECEIVER  

ROP-22

TECHNICAL DATA

Nominal supply voltage:

230 VAC 

Nominal frequency: 50/60 Hz

50 / 60 Hz

Nominal power consumption:

0,45 W – standby

0,8 W – one channel operation 

1,2 W – two channel operation

Transmission:

radio – ISM band 868 MHz

Transmission way:

two-way - 9600 bps

Coding:

algorithm based on 128-bit key

Operating range:

up to 330 m in the open area

Optical signalling 

(transmission / programming):

yes – RGB LED 

Number of paired buttons:

maximum 96 pairs

Current receiver’s mode information:

yes – in the EXTA LIFE mobile application

Operating modes in cooperation 

with EXTA LIFE system transmitters:

switch on /switch off, bistable, monostable, time

Operating modes in cooperation 

with EXTA LIFE controller:

switching on, switching off, time

Number of external inputs:

2

Cooperation with push-buttons*:

monostable (push-buttons), bistable

Operating modes for external inputs**: switching on, switching off, bistable, monostable, 

time

Time adjustment range:

1 sec. ÷ 18 hrs.

Number of output channels:

1

Relay contact parameters:

2 x NO 5A / 250 VAC (voltage output) 

Maximum output load:

incandescent and halogen lighting sources – 750 W 

LEDs – 60 W

CFL lamps – 250 W

Number of terminal clamps:

6 (wires with cross-section up to 2,5 mm2)

Casing mounting:

Ø60 mm junction box

Operating temperature range:

-10 do +55 °C

Protection degree:

IP20

Protection class:

II

Dimensions:

47,5 x 47,5 x 20 mm

Weight:

0,04 kg

Reference standards:

EN 60669, EN 60950, EN 61000

ETSI EN 300 220-1, ETSI EN 300 220-2

*  switch type configured by means of the EXTA LIFE mobile application

** operating mode dependent on selected switch type

MOUNTING

•  The ROP-22 receiver is designed to be mounted in a junction box. Its dimensions enable 

flush (Ø60 minimum) and surface mounting. In case of a flush junction box, a deepened 

box is recommended, as it makes mounting easy with a large number of wiring and a big 

cross-section of connection wires.

•  The device is designed for single-phase installation and must be installed in accordance 

with standards valid in a particular country. The device should be connected according to 

the details included in this manual instruction. Installation, connection and control should be 

carried out by a qualified electrician staff, who act in accordance with the service manual 

and the device functions. For safety reasons, do not mount the device without casing or with 

a damaged one, as an electric shock may occur. 

•  After power supply has been applied, the receiver will carry out service activities for about 

5 seconds (it is signalled by a green STATUS LED, it will flash at an interval of 1 second). 

During this time the receiver’s control is not possible.

CAUTION: Before installation make sure the connection cables are not under voltage. 
INSTALLATION:

1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch-disconnector 

combined to the proper circuit.

2. Check  if  there  is  no  voltage  on  the  connection  cables  by  means  of  a  special  measuring 

equipment.

3. Connect the device cables with the terminals in accordance with the installing diagram.

4. Install ROP-22 in a junction box.

5. Switch on the power supply from the mains.

MOUNTING REMARKS

1. Do not mount receivers in a close proximity to each other (if there is a possibility, keep a dis-

tance of minimum 15 cm between receivers). Particularly, avoid installation of one receiver 

over the another.

2. The maximum output load must be obeyed:

•  incandescent and halogen lamps: 750 W / channel,

•  fluorescent CFL lamps: 250 W / channel,

•  dimmable LEDs: 60 W / channel.

3. During mounting, make sure the receiver is not exposed to direct water and operation in an 

increased humidity environment. The mounting ambient temperature range should be within 

the range from -10 to + 55 °C.

4. The ROP-22 receiver is designed to be mounted indoor. In case the receiver is mounted 

outdoor, it must be placed in an additional hermetic casing.

5. Wired control switches can be connected to the IN1 and IN2 inputs of ROP-22 receiver. By 

default,  the  inputs  are  adapted  to  cooperate  with  monostable  push-buttons  in  a  bistable 

mode. It means that each subsequent impulse given to the IN1 or IN2 input causes the output 

mode is changed to an opposite mode.

6. After a receiver has been installed, it is important to check, if it operates correctly. In case of 

control by means of the EXTA LIFE system transmitters, they must be first programmed with 

a receiver (see Programming transmitters). In case of cooperation with a controller, a correct 

pairing of a receiver with a controller is required (see Register of receivers in the EXTA LIFE 

system).

CAUTION: Input functionality (switch type, operation mode) can be changed by means 

of the EXTA LIFE mobile application. It is necessary to install a controller in the system 

and pair it with ROP-22 receiver – see Input functionality.