background image

VER. 003_20.05.2011

COOPERATION AND OPERATING RANGE

Symbol

ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01

RNK-02

180 m

200 m

200 m

200 m

200 m

250 m

180 m

250 m

250 m

180 m

250 m 

RNK-04

180 m

200 m

200 m

200 m

200 m

250 m

180 m

250 m

250 m

180 m

250 m 

P-256/8

230 m

250 m

250 m

250 m

250 m

300 m

200 m

300 m

300 m

230 m

300 m 

P-257/4 (2)

180 m

200 m

200 m

200 m

200 m

250 m

180 m

250 m

250 m

180 m

250 m 

RNM-10

230 m

250 m

250 m

250 m

250 m

300 m

200 m

300 m

300 m

230 m

300 m 

RNP-01

160 m

180 m

180 m

180 m

180 m

200 m

160 m

200 m

200 m

160 m

200 m 

RNP-02 

160 m

180 m

180 m

180 m

180 m

200 m

160 m

200 m

200 m

160 m

200 m 

RNL-01

160 m

180 m

180 m

lack*

lack*

200 m

160 m

200 m

200 m

160 m

200 m 

RTN-01

200 m

200 m

200 m

200 m

200 m

250 m

200 m

250 m

250 m

200 m

250 m 

RCR-01

160 m

180 m

180 m

lack*

lack*

200 m

160 m

200 m

200 m

160 m

200 m 

RTI-01

160 m

180 m

180 m

180 m

180 m

200 m

160 m

200 m

200 m

160 m

200 m 

RXM-01 

230 m

250 m

250 m

250 m

250 m

300 m

200 m

300 m

300 m

230 m

300 m 

* - 1-channel transmitters do not cooperate with roller blind controllers.

CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles between a transmitter and a receiver, 

it is advisable to decrease the range according to: wood and plaster: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %, metal: from 90 to 100%,

glass: from 10 to 20 %, Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device system have 

also a negative influence on the range.

RADIO TRANSMITTERS PROGRAMMING

ROP-01 OPERATION

ROP-01 can operate in five modes:

MONOSTABLE

the  relay  operates  only 

while  pressing  transmit-

ter’s push-button. 

BISTABLE

(one  push-button)  the 

device  changes  relay 

status cyclically always 

after  pressing  the  same  push-

-button.

SWITCH ON

the  device  switches  on 

after pressing the push-

-button.

SWITCH OFF

the  device  switches  off 

after pressing the push-

-button.

TIME

the  device  switches 

off  according  to  the 

adjusted time (tp), 

but it may be switched off before 

adjusted  time  finishes.  Default 

settings - 15 seconds. 

CAUTION! Adjusted time can 

not be deleted. 

TIME PROGRAMMING

RADIO TRANSMITTERS DELETION

TRANSMITTERS

RECEIVERS

RNK-02

2–channel button  

radio transmitter

RNL-01

Radio 

foot transmitter

ROP-01

1-channel 

radio receiver

RWL-01 

Radio lighting 

switch

RNK-04

4-channel button 

radio transmitter

RTI-01

IR/EXTA FREE 

transceiver

ROP-02

2-channel 

radio receiver

RWG-01 

Remote control 

socket

P-256/8

8-channel 

remote controller

RNM-10

4-channel radio 

modular transmitter

RDP-01

1-channel 

radio dimmer

SRP-02 

Radio roller blinds 

controller

P-257/4

4-channel 

remote controller

RNP-01

4-channel 

radio transmitter

ROB-01/12-24V

Radio 

gate controller

SRP-03 

Central radio roller 

blinds controller

P-257/2

2-channel 

remote controller

RNP-02

4-channel 

radio transmitter

ROM-01

1-channel radio 

modular receiver 

ROM-10

2-channel 

radio modular receiver

RCR-01

Radio 

motion sensor

RXM-01 

Translator

RS-485/EXTA FREE

ACCESSORIES

ANT-01 

External antenna

RTN-01

Retransmitter

MONOSTABLE

 mode:

BISTABLE

 mode:

SWITCH ON/SWITCH OFF

 mode (two push-buttons):

TIME

 mode (one push-button):

An exemplary programming procedure with the use of P-257/2 remote controller. The procedure for the rest of radio EXTA FREE transmitters 

is analogous. 

CAUTION: Every transmitter can cooperate with ROP-01 in a different mode, depending on how they were added to 

the device. One transmitter can be added during one programming cycle. Full memory is signalled with pulsating LED red diode.

Press transmitter’s 

push-button for 

a longer time.

Press the transmitter’s push-button 

for a longer time. LED red diode 

switches on (first signal pulsates, 

next the signal is constant). 

Press transmitter’s push-button and then 

release it. LED red diode switches on

(first signal pulsates, next 

the signal is constant).

Press and release transmitter’s 

push-button. LED red diode 

switches on (first signal pulsates, next 

the signal is constant).

Release transmitter’s push-

button. LED red diode switches 

on (first signal pulsates, 

next the signal is constant). 

Release transmitter’s push-button. 

LED red diode switches on (the 

signal pulsates), next the LED red 

diode switches off - it means the 

TRANSMITTER IS ADDED.

Press and release the same transmitter’s 

push-button. LED red diode switches on 

(signal pulsates) and then switches off -  

THE TRANSMITTER IS ADDED.

Press and release the same transmitter’s 

push-button. LED red diode switches on 

(the signal pulsates) and next it switches 

off - THE TRANSMITTER IS ADDED.

Press the same transmitter’s push-

-button and release it. LED red 

diode switches on (the signal pulsa-

tes) and next it switches off - THE 

TRANSMITTER IS ADDED.

Press PROG push-button of ROP-01 device 

for a longer time until LED red diode 

switches on (constant signal). 

Next release PROG push-button.

Press PROG push-button of ROP-01 device 

for a longer time until LED red diode 

switches on (constant signal). 

Next release PROG push-button.

Press PROG push-button of ROP-01 device 

for a longer time until LED red diode 

switches on (constant signal). 

Next release PROG push-button. 

Press PROG push-button of ROP-01 device 

for a longer time till LED red diode 

switches on (constant signal). 

Next release PROG push-button.

Maximum time is 18 hours.

Press PROG push-button of ROP-01 device for a longer time till 

LED red diode switches on (constant signal). Next release PROG 

push-button. Wait (for about 5 seconds) till LED red diode switches 

on (first signal pulsates, next the signal is constant).

After the adjusted time is 

finished (the number 

of LED red diode flashes) 

press PROG  push-button 

and then release it 

- TIME IS ADDED.

Press PROG push-button of ROP-01 device 

and then release it. LED red diode switches 

off and then switches on (signal pulsates). 

Every LED diode pulse equals 1 second.

Press PROG push-button of ROP-01 

device for a longer time.

After 5 seconds LED red diode switches on 

(signal pulsates) and then it switches off.

Release the push-button in ROP-01 - 

MEMORY IS DELETED.

1s 2s

ns

Отзывы: