background image

CONNECTING DIAGRAM

EXAMPLE OF INSTALLATION

ver. 0.4.1 _ 2006.06.27_14:00

FUNCTIONING

The system works properly after swit-

ching on the power supply from the mains. 

Turning  the  potentiometer  in  the  direction 

of  “ “  causes  the  lighting  device  to  switch 

on at lower lighting level, in the direction of 

“☼“ causes the device to switch on at higher 

lighting level. In case the inner sensor’s lumi-

nous flux density falls below the preset thres-

hold the system switches on the output relay 

and its lighting devices. The relay is switched 

on until the luminous flux density is over the 

preset  threshold.  Using  the  luminous  flux 

density hysteresis (delta) and relay switching 

off time delay (T) makes the system resistant 

to  momentary  and  accidental  light  pulses. 

While mounting the twilight switch pay atten-

tion the switched on lighting does not disturb 

the functioning of the twilight lighting sensor.

DIMENSIONS

INNER DIAGRAM

TIME COURSE

PRODUCT FAMILY

The twilight switch WZH-01 belongs to the 

twilight switches WZx family.

MOUNTING

1. Disconnect the power supply from the ma-

ins by the phase fuse, the circuit-breaker or 

the switch-disconnector that are joined to the 

proper circuit.

2.  Check if there is no voltage on connec-

tion cables by means of a special measu-

re equipment.

3.  Fasten  the 

WZH-01

  to  the  base  with  the 

screw.

4.  Connect  the  cables  WZH-01  with  the  her-

metic  installation  junction  box  according  to 

installing diagram.

5.  Switch on the power supply from the mains.
6.  Take out the rubber hole plug covering the 

adjustment of the switch on threshold poten-

tiometer.

7.  Adjust the demanded switch on threshold.
8.  Put back the rubber hole plug covering the 

potentiometer.

Typical application:

The  twilight  switch  operates  the  light  control  functions  (for  example  garden 

lighting). The device should be installed in a place which is not directly illuminated 

by lights that are operated by this twilight switch.

RELAY CAPACITY

WZx - xx (/ S1)

Version:

01 - one range

02 - two ranges (only 

type M casing)

Type of casing:

M - monomodular

N - surface mounting

H - hermetic

S - special

Symbol

Probe SOH-01

brown

grey

black

blue

black

blue

grey

brown

b

la

ck

blue

g

r

ey

br

o

wn

luminous flux 

density

200 lx

35 lx

20 lx

2 lx

position of 

potentiometer

0 lx

200 lx

0 lx

200 lx

0 lx

200 lx

0 lx

200 lx

t

t

L, N

lx

T

t

∆ ≈ 5 ÷ 60 lx

T ≈ 30 s

Отзывы: