background image

RTM - 02 TEMPERATURE REGULATOR 

INSTRUCTION

FEATURES

TECHNICAL DATA

DESCRIPTION

APPEARANCE

RTM-01

Power supply terminals: L, N

Input rated voltage: 230 V~

Rated voltage tolerance: -15 ÷ +10 %

Nominal frequency:  50 / 60 Hz

Rated power consumption: 33 mA

Supply voltage indicator: green LED

NTC sensor terminals: IN, IN

Temperature adjustment range: -10°C ÷ +40°C

Hysteresis: ±1 

o

C

Relay terminals: 11, 12, 14

Load supply indicator: red LED

Relay contacts parameters: 16A NO/NC 4000 VA  AC1

Number of terminal clamps:  7

Section of connecting cables:  0,2 ÷ 2,50 mm

2

Ambient temperature range: -20 ÷ 60 

o

C

Operating position: free

Mounting: TH 35 rail (according to PN PN-EN 60715)

Protection degree: IP20 (PN-EN 60529)

Protection level:  II

Overvoltage category: II

Pollution degree: 2

Dimensions: single-module (17,5 mm) 90x17,5x66 mm

Weight: 0,08 kg

Reference standards: PN-EN 60730-1, PN-EN 60730-2-9

PN-EN 61000-4-2,3,4,5,6,11

●  Temperature control in a range of  

-10°C ÷ +40°C,

●  External NTC probe,
●  Power supply indicator,
●  Relay state indicator,
●  Load control in dependence of ambi-

ent temperature,

●  Single-module casing,
●  Mounted on TH 35 rail,
●  Relay output, maximum load 16 A.

The RTM-01 temperature regulator is 

designed  for  load  control  (e.g.  heaters, 

floor heating systems) in dependence of 

ambient  temperature,  near  NTC  sensor. 

The device is capable of temperature 

regulating in the range of -10°C ÷ +40°C 

according to the temperature adjusted 

by means of a potentiometer on the 

unit  front  panel.  The  external  NTC-03 

temperature probe is needed for correct 

system  operation. The  probe  is  not  part 

of the set and it is necessary to purchase 

it  separately.  The  probe  lead  is  3  m  in 

length.  It  is  possible  to  extend  it  up  to  

50 m with 0,2 ÷ 2,5 mm

2

 lead. Do not join 

the probes.

The device is designed 

for single-phase installa-

tion and must be installed 

in accordance with stand-

ards valid in a particular 

country. The device should 

be connected according to 

the details included in this operating man-

ual.  Installation,  connection  and  control 

should be carried out by a qualified electri-

cian staff, who act in accordance with the 

service manual and the device functions. 

Disassembling of the device is equal with 

a loss of guarantee and can cause electric 

shock.  Before  installation  make  sure  the 

connection cables are not under voltage. 

The cruciform head screwdriver 3,5 mm 

should  be  used  to  instal  the  device.  Im-

proper transport, storage, and use of the 

device influence its wrong functioning. 

It is not advisable to instal the device in the 

following cases: if any device part is miss-

ing or the device is damaged or deformed. 

In case of improper functioning of the de-

vice contact the producer.

ON threshold setting

Supply voltage indicator

Power terminal (L)

Power terminal (N)

Relay state indicator

Relay output terminals
(11, 12, 14)

Sensor input terminals 

(IN, IN)

NTC probe

ZAMEL 

Sp. z o.o.

ul. Zielona 27, 43-200 Pszczyna, Poland

Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04

www.zamelcet.com

, e-mail: [email protected]

Отзывы: