1. Isolate from power the wiring system 

to be connected with this product with 

its circuit breaker, overcurrent device or 

disconnector, as applicable.

2.  Use a suitable tester to verify that the 

isolated power input wiring is not live.

3.  Install the PMM-02 on a DIN Rail in the 

respective switchboard.

4.  Connect the wiring to the terminals, see 

the applicable wiring connection dia-

gram.

5.  Turn on the power of the connected wir-

ing system.

6. Set the desired power threshold and 

power load trip-off delay.

The control circuit limits the controlled 

power load. When the total power load 

demand on the controlled power line is be-

low the power threshold setting, the power 

loads remain on the rated supply voltage. 

When the power load demand exceeds the 

power threshold setting, the power load line 

is isolated from voltage (powering down the 

controlled power loads). The supply voltage 

is reapplied to the power loads to test the 

power load value when the set trip-on delay 

expires. Following this power load test, the 

control circuit determines if the supply volt-

age should be reapplied or the power loads 

left off. Fine-tune the power threshold after 

approximately 40 minutes of operation.

APPLICATION

DIMENSIONS

PRODUCT FAMILY

WARRANTY CARD

There is 24 months guarantee on the product

Salesman stamp and signature, date of sale

The power limiter can support a staircase lighting timer to form a timer-controlled lamp 

power system with a power load limit. Having determined the power load demand in the 

control system and with the power limiter’s power threshold set, the system prevents con-

nection and operation of illegal power loads with the control system. Hence, if there is a 

power overload which exceeds the power threshold, the power limiter isolates the supply 

voltage from the controlled power line and periodically retest the power demand for com-

pliance with the power threshold setting.

The PMM-02 is a model from the PMX range 

of power limiters.

PMM-02 

ASM-01

PMX - 02

Product version

Product type code

Enclosure type:

M – single-module

H – water-tight

1.  ZAMEL provides a two-year warranty for its products. 

2.  The ZAMEL warranty does not cover: 

  a) mechanical defects resulting from transport, loading / unloading or other circumstances 

  b) defects resulting from incorrect installation or operation of ZAMEL products; 

  c) defects resulting from any changes made by CUSTOMERS or third parties, to products sold or equipment necessary for the correct 

operation of products sold; 

  d) defects resulting from force majeure or other aleatory events for which ZAMEL is not liable; 

  e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear); 

3.  All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.; 

4.  ZAMEL will review complaints in accordance with existing regulations.; 

5.  The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. 

6.  Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy be-

tween the goods and the contract.

10s ÷ 90s

10s ÷ 90s

10s ÷ 90s

0,25s

0,25s

PMM-02 

ASM-01

ASM-01

Отзывы: