Upper Boom Control Switch
•
The upper boom switch initiates or turns off flow from the upper boom.
Lower Boom Control Switch
•
The lower boom switch initiates or turns off flow from the lower boom.
Water Application Rate Scaling Switch
•
This switch allows the operator to increase or decrease the water flow rate from as low as 50%
of its pre-calibrated value to as high as 150% of its pre-calibrated value.
-
The factory-set system flow rates are 10.5 GPM from the Upper Boom and 3.8 GPM
from the Lower Boom at a 5 MPH reference speed. The total flow from both
booms for these flow rates is 14.3 GPM.
Blast Button
•
This function allows the operator to apply the maximum water flow rate set in the control
system for up to 10 seconds at a time.
-
The factory setting for the maximum water flow rate is 25.7 GPM.
Training Manual
Zamboni FastICE
®
Training Manual
DK - 11001
Page 8 of 20