User's manual
OREX 1 luminaire
No. 52-1200/Z
Revision 1
Page 4
5.
Maintenance and repairs
The design of the luminaire makes it possible to replace the light source and power supply
unit (except for the version for zone 1), which should be carried out by an authorised service. The
lifetime of the light source and LEDs depends on the ambient temperature of the luminaire and its
power. If the luminaire is damaged, it should be replaced with a new or repaired by an authorised
service.
Due to the explosion-proof design, any maintenance works related to the de-
vice (except for spare parts replacement specified in this manual) may only be
conducted by the manufacturer service or by an entity authorised by the man-
ufacturer with appropriate service documentation.
6.
Transport and storage
6.1.
Transport
The originally packed devices should be transported using covered means of transport. The
packaging should be secured against shifting and sudden shocks. Devices should be transported at a
temperature not lower than -20°C and not higher than +50°C.
6.2.
Storage
The equipment should be stored horizontally in closed areas at a temperature not lower than -
5°C and not exc40°C and away from heaters.
7.
Additional information
7.1.
CE marking
The CE marking has been affixed under the following regulations:
Explosion-proof equipment
–
Directive 2014/34/EU (ATEX)
Electromagnetic compatibility -
Directive 2014/30/EU (EMC)
Restriction of hazardous substances
–
Directive 2011/65/EU (RoHS II)
Information on the obtained certificates and standards applied to the equipment evaluation has been
specified in the declaration of conformity attached to every copy of the device.
The harmonised standards applied to demonstrate the compliance with the relevant directive are set
out in the EU declaration of conformity supplied together with the device.
7.2.
Special conditions for safe use
•
for luminaires up to 100 W -32
C ≤ Tamb ≤+55
C
•
for luminaires over 100 W -32
C
≤ Tamb ≤+50
C
7.3.
Basic safety principles
•
Before attempting any works related to the equipment, the provisions of this manual should be
read thoroughly.
•
Follow good engineering practices during the selection of the equipment for a given applica-
tion, during installation and during operation.
•
The device should only be operated by personnel trained for this purpose.
•
The safety rules of this type of equipment should be observed.
•
Prior to the installation, check whether the marking on the rating plate satisfies requirements
for a given application.
•
Following the guidelines of the manual is a condition for warranty claims.