background image

11

1. Warnings and Safety Precautions

2. Components

  

Opening the cover of the product while the power cord is plugged into an outlet 

     may cause electrocution or critical damage to the product.

  Handling the power cord with wet hands may cause electrocution.

 Inserting ingers or metallic objects into the cooling fan may cause injury or 

     electrocution.

  

Operating the product in an extremely cold or hot environment can degrade 

     product performance and lifespan.

  Exposure to liquids may cause malfunction.

 Operation in a humid or non-ventilated environment may reduce product lifespan.

 

Plugging the main power connector P1 into the motherboard while the product is   

    connected to the AC power source may cause damage to the motherboard.

  Make sure that the connectors are connected to their designated locations, and 

    that the connectors are not oriented in the wrong direction when connecting the 
    DC output connectors.

 Please use gloves to prevent injuries during installation.
  Product designs and speciications may be revised without prior notiication to 

    improve quality and performance.  

Neglecting the following may cause serious injury or death.

Neglecting the following may cause minor injuries, degrade product 

conditions or cause malfunction.

Caution

Warning

Power Supply

AC Power Cord

Four Screw

Five Cable Ties 

User’s Manual

Disclaimer)  Zalman Tech Co., Ltd. is not responsible for any damages due 

to external causes, including but not limited to, improper use, 

problems with electrical power, accident, neglect, alteration, 

repair, improper installation, or improper testing.

Содержание ZM500-GT

Страница 1: ...User s Manual ZM500 600 700 GT Ver 1 0 www ZALMAN com To ensure safe and easy installation please read the following precautions Two Forward Switching Power Supply ...

Страница 2: ...ower source may cause damage to the motherboard Make sure that the connectors are connected to their designated locations and that the connectors are not oriented in the wrong direction when connecting the DC output connectors Please use gloves to prevent injuries during installation Product designs and speciications may be revised without prior notiication to improve quality and performance Negle...

Страница 3: ... Operation 0 40 3 3VDC 5 3 14 3 47V Stored 20 80 5VDC 5 4 75 5 25V Ambient Humidity 12V1DC 5 11 4 12 6V Operation 5 95 RH 12V2DC 5 11 4 12 6V Stored 5 95 RH 12VDC 10 10 8 13 0V Dimensions 140 L 150 W 86 H 5VSB 5 4 75 5 25V Weight 2 17Kg Full Package DC Output Ripple Noise Vout Standard Range At Full Load Safety Features 3 3VDC 50mV Over Voltage Protection OVP 5VDC 50mV Under Voltage Protection UVP...

Страница 4: ... 40 12V1DC 5 11 4 12 6V Stored 20 80 12V2DC 5 11 4 12 6V Ambient Humidity 12V3DC 5 11 4 12 6V Operation 5 95 RH 12V4DC 5 11 4 12 6V Stored 5 95 RH 12VDC 10 10 8 13 0V Dimensions 5VSB 5 4 75 5 25V 140 L 150 W 86 H DC Output Ripple Noise Vout Standard Range At Full Load Weight 3 3VDC 50mV 2 46Kg Full Package 5VDC 50mV Safety Features 12V1DC 120mV Over Voltage Protection OVP 12V2DC 120mV Under Voltag...

Страница 5: ...1 4 12 6V Stored 20 80 12V2DC 5 11 4 12 6V Ambient Humidity 12V3DC 5 11 4 12 6V Operation 5 95 RH 12V4DC 5 11 4 12 6V Stored 5 95 RH 12VDC 10 10 8 13 0V Dimensions 5VSB 5 4 75 5 25V 140 L 150 W 86 H DC Output Ripple Noise Vout Standard Range At Full Load Weight 3 3VDC 50mV 2 50Kg Full Package 5VDC 50mV Safety Features 12V1DC 120mV Over Voltage Protection OVP 12V2DC 120mV Under Voltage Protection U...

Страница 6: ...5 5 4 Certiications E198072 ...