3.3.
Control ports REMOTE GPI
All control outputs are designed to be interfaced with 5V logic circuitry.
Important Note:
Connect DC in the 0-5V range to the control inputs only. Control outputs may only be
connected to circuits which operate in the 0-5V DC range. Never connect any supply voltage directly to a
control output. Refer to chapter „Technical Data“ to find information about maximum allowable current.
Exceeding any limits can cause damage on the unit or the circuitry you connect.
Refer to chapter „Technical Data“ for more details about circuitry and connection.
3.4.
Lamp Supply/USB
Right hand on the front panel there is a USB Type A socket designated “DC ONLY”. It serves exclusively
for supplying a standard 5V LED Lamp with USB connector (commercially available with gooseneck).
Important Note:
Never connect any other equipment. Especially never connect a PC or PC peripheral
equipment to this USB socket. There is the danger of damage to your AIRCOM as well as the connected
equipment.
More details about technical data, functions and connector pin-outs are specified in the following
chapters of this manual.