8.10 Calibrate Joystick (#33)
Firmware Version:
Version 5.04 and up
Command Number:
33
Data Bytes:
Specifies the calibration mode:
1 – calibrate limits
2 – calibrate dead-bands
0 – stop calibrating, save calibration data, and return to normal operation.
Reply Data:
The reply is simply an echo of the instruction.
Note:
Calibration settings are a special case in that they are not affected by a Restore
Settings (#36) instruction. There are no factory default calibration settings that
will work well on all T-JOY units, and it would be a tedious matter to re-calibrate
after every Restore Settings (#36) instruction. The calibration settings are stored
in non-volatile memory and will persist after power-down or reset.
This instruction is used to calibrate the joystick. There are two sets of calibration variables: limits and dead-
bands. Limits define the maximum angular displacement of all axes of manipulation. Dead-bands define
the area around the neutral position of the joystick where no action should occurs. Dead-bands are useful to
adjust the sensitivity of the joystick to vibration or accidental movement from the neutral position.
The T-JOY is pre-calibrated before shipping so that it should work well right out of the box. Note that
restoring default settings using command #36 will have no affect on the joystick calibration. There is no
default calibration since each joystick has slightly different properties that prevent a single set of settings
from working well on all devices.
Page 21 of 32