5.5.2 Start Speed
This command enables the user to set the starting microstep period of the actuator (command 41)
which controls the start speed. Please see the user manual of the actuator for more detail on this
setting.
Start Speed:
0000096
Y
Ok
Y
Back
Y
The display shows the current setting retrieved from the actuator. Turning the rotary knob
changes the digit highlighted by the blinking cursor, while pressing the button next to the number
advances the cursor to the next digit. Pressing “Ok” sets the new value for the selected actuator,
while “Back” cancels the operation without changing the value.
5.5.3 Target Speed
This command enables the user to set the target microstep period of the actuator (command 42)
which controls the running speed. Please see the user manual of the actuator for more detail on
this setting.
Target Speed:
0000048
Y
Ok
Y
Back
Y
The display shows the current setting retrieved from the actuator. Turning the rotary knob
changes the digit highlighted by the blinking cursor, while pressing the button next to the number
advances the cursor to the next digit. Pressing “Ok” sets the new value for the selected actuator,
while “Back” cancels the operation without changing the value.
Copyright © Zaber Technologies Inc.
Page 16 of 22