4
CONFIDENTIAL
DOC-PRO-0049-02
___________________________________________________________________________________________
Z3 Technology, LLC
♦
100 N 8
th
ST, STE 250
♦
Lincoln, NE 68508-1369 USA
♦
+1.402.323.0702
1.0
REQUIRED MATERIALS
1x Z3-DM8107-MOD-02
1x Z3-DM8107-APP-21
1x Z3-DME-03 enclosure
2x FFC/Ribbon
Cables (pitch 0.5mm, 40 pin, length 49mm)
1x 5V DC Fan (SUNON Part# MC3010
0
V1-000U-A99)
4x Silver Pan Head Screws (3x4mm)
Inside
2x Black Flat Head Screws (3x4mm)
Outside
3x Black Flat Head Screws (3x14mm)
Fan
3xSilver Nuts (M3)
For assembly, always use a torque screwdriver. The default is to set it to 10 lbs of torque.
2.0
ASSEMBLY INSTRUCTIONS
(1)
Place the module and APP board on an anti-static mat. Insert the Z3-DM8107-MOD-02 into the Z3-
DM8107-APP-21 and use 2x ribbon cables to connect the module and APP on the other end. However,
Figure 1 below shows the wrong ribbon cable position because this will prevent the air flow from the fan
once the module and APP board are placed in the enclosure.
Figure 1 Wrong ribbon cable position
(2)
The ribbon cable on the right should be folded inwards so the folded part will be in between the module