![Z3 Technology FV2K-DCK-1x Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/z3-technology/fv2k-dck-1x/fv2k-dck-1x_user-instructions_3100628054.webp)
FV2K-DCK-1X User Instructions
DOC-USR-0121-09
______________________________________________________________________________________
Z3 Technology, LLC
♦
100 N 8
th
ST, STE 250
♦
Lincoln, NE 68508-1369 USA
♦
+1.402.323.0702
54
(9)
You can return to the use of limited settings by un-checking the
Advanced Settings
box in the
System Setup tab and saving that to the preset.
8.3
Channel 2 PIP on Channel 1
The FV2K-DCK-1X allows for the Picture in Picture (PIP) of channel 2 to be placed on the channel 1
stream. A common case is to have a PIP of the IR camera on the stream for the visible video.
1.
Start channel 1 from the CH1 tab.
2.
On the CH2 tab under Output Setup select “True” from the Chann
el 1 PIP Enable dropdown.
3.
A PIP Location dropdown will appear. Select the desired location from the dropdown and click
“start”.
Figure 62 PIP Configuration
Note:
The PIP stream needs to be set to a resolution that is smaller than the resolution of Channel 1. If Channel
2 not a smaller resolution the PIP will not show on Channel 1.
8.4
Encoder ROI
The FV2K-DCK-1x allows for the encoding of a Region of Interest (ROI) in the captured video. This allows
the encode of only the region of the video you are interested in.