32
Z-Wave Configuration Parameters
Different user has different preferred settings of their thermostat, you may use the
below configuration parameters to change settings of corresponding functionality.
500 (0x01F4) to 4000 (0x0FA0) hours
Default = 500 (0x01F4) hours
Resolution = 100 (0x0064) hours
3 (0x03)
Set filter counter
Parameter value range
Parameter No.
o o
1 (0x01) = 1 F / 0.5 C
o o
2 (0x02) = 2 F / 1.0 C
(default)
o o
3 (0x03) = 3 F / 1.5 C
o o
4 (0x04) = 4 F / 2.0 C
1 (0x01)
o o
1 (0x01) = 1 F / 0.5 C
o o
2 (0x02) = 2 F / 1.0 C
(default)
o o
3 (0x03) = 3 F / 1.5 C
o o
4 (0x04) = 4 F / 2.0 C
2 (0x02)
Functions
Swing
Differential
0 (0x0000) to 9999 (0x270F) hours
4 (0x04)
Dead band value:
3(0x03)= 3
/ 1.5
4(0x04)= 4
/ 2.0
5(0x05)= 5
/ 2.5
6(0x06)= 6
/ 3.0
o o
F
C
o o
F
C
(default)
o o
F
C
o o
F
C
14 (0x0E)
o
0 (0x00) = C
o
1 (0x01) = F
(default)
5 (0x05)
Report filter counter
(read only)
D e a d b a n d
(On thermostats that
automatically control
both heating and
cooling systems, a
d e a d b a n d i s a
temperature range in
which neither system
turns on. The dead
band prevents the
t h e r m o s t a t f r o m
activating heat and
c o o l i n g i n r a p i d
s u c c e s s i o n . T h i s
conserves energy by
providing a range of
t e m p e r a t u r e s
requiring no energy
consumption)
Scale of temperature