Z-Wave Aeotec 7 Pro Скачать руководство пользователя страница 7

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can 

adapt the function better to user needs or unlock further enhanced features. 

IMPORTANT:

 Controllers may only allow configuring signed values. In order to set values in the range 

128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a 

parameter to 200

it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte 

value the same logic applies: Values greater than 32768 may needed to be given as negative values too. 

Parameter 1: Sensor Operation Mode 

This parameter defines if the internal magnet sensor or the external terminal input is detected and used to 
issue alarm notification. The other sensor input the deactivated. If the parameter is set to 1, the scene 
activation for the external terminal input will be deactivated. 

 

Size: 1 Byte, Default Value: 0 

Setting 

Description 

Internal Magnet Sensor Used and scene activation enabled 

External Terminal Inputs Used and scene activation disabled 

Note:

 Quick press the button 5 times, which can also toggle parameter 1 setting value from 0/1.

 

 

Parameter 2: Dry Contact Operation Mode 

This Parameter defines how dry contact will operate with the sensor or switch that is connected to the dry 
contact terminals.

 

Size: 1 Byte, Default Value: 0 

Setting 

Description 

NO Toggle / Follow state will follow the input of the dry contact terminals 

where OFF is CLOSED, and ON is OPEN. 

NC Toggle / Follow state will follow the input of the dry contact terminals 

where ON is CLOSED, and OFF is OPEN. 

NO save state will allow state of sensor to toggle OPEN/CLOSE based on 

OFF to ON signal. 

NC save state will allow state of sensor to toggle OPEN/CLOSE based on 

ON to OFF signal. 

 

Parameter 3: Door/window state 

This parameter allows to set in what state is door/window when the magnet is close to the sensor.

 

Size: 1 Byte, Default Value: 0 

Setting 

Description 

Closed when Magnet near 

Opened when Magnet near 

Parameter 4: Visual LED Indications 

Содержание Aeotec 7 Pro

Страница 1: ...Door Window Sensor 7 Pro ...

Страница 2: ... way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter This device and every other certified Z Wave device can be used together with any other certified Z Wave device regardless of brand and origin as long as both are suited for the same frequency range If a device supports secure ...

Страница 3: ... into factory default You can do this by performing an Exclusion operation as described below in the manual Every Z Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network Reset to factory default This device also allows to be reset without any involvement o...

Страница 4: ...ed Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller is turned into exclusion respective inclusion mode Inclusion and Exclusion is then performed doing a special manual action right on the device Inclusion 1 Open the housing 2 Remove the battery protection 3 Press the tamper on the side of the appliance three times quickly Exclusion 1 Open the h...

Страница 5: ...mper will start the process As a result the GREEN LED will blink two times in case of success and the RED LED will blink two times in case of failure Scene Controller When activated by configuration parameter 14 the device can perform as a scene controller Digital VCC is used to connect the scene button The external dry contact will then act as a scene controller with a total of 7 scenes that can ...

Страница 6: ...firmware over the air The update function needs to be supported by the central controller Once the controller starts the update process perform the following action to confirm the firmware update Wake Up the device by removing the cover Then hit the tamper switch once Association one device controls another device Z Wave devices control other Z Wave devices The relationship between one device cont...

Страница 7: ...0 Setting Description 0 Internal Magnet Sensor Used and scene activation enabled 1 External Terminal Inputs Used and scene activation disabled Note Quick press the button 5 times which can also toggle parameter 1 setting value from 0 1 Parameter 2 Dry Contact Operation Mode This Parameter defines how dry contact will operate with the sensor or switch that is connected to the dry contact terminals ...

Страница 8: ... failure Size 1 Byte Default Value 0 Setting Description 0 Disabled 1 Enabled Parameter 6 2nd Association Group Trigger This parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 2 Size 1 Byte Default Value 0 Setting Description 0 Switch after Open and Close 1 Switch after Open 2 Switch after Close Parameter 7 Command Sent to Devi...

Страница 9: ...escription 0 32400 seconds Parameter 11 Time Delay of Off command frame Off command is sent after a delay defined in this parameter Size 2 Byte Default Value 0 Setting Description 0 32400 seconds Parameter 12 Delay of Tamper Alarm Cancellation Time a tamper alarm is delayed Size 2 Byte Default Value 0 Setting Description 0 32400 seconds Parameter 13 Reporting Tamper Alarm Cancellation This paramet...

Страница 10: ... OFF state Size 1 Byte Default Value 0 Setting Description 0 OFF when sensor is vertical 1 ON when sensor is vertical Parameter 17 5th Association Group Trigger This parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 5 Size 1 Byte Default Value 0 Setting Description 0 Switch after Open and Close 1 Switch after Open 2 Switch aft...

Страница 11: ...lt sensitivity With this parameter you can adjust the tilt sensitivity if the tilt is too low or too strong Value 0 does not disable Tilt Sensor it just sets it to a minimum Size 1 Byte Default Value 50 Setting Description 1 100 Sensitivity Parameter 22 Enalbe disbale Binary Sensor report Backwards compatibility Binary Sensor for door window state Sensor type 0x0A Size 1 Byte Default Value 0 Setti...

Страница 12: ...rameter settings to their default settings 1431655765 Completely factory reset sensor and send device reset locally notification Technical Data Dimensions 28x95x35 mm Hardware Platform ZGM130S IP Class IP 20 Battery Type 1 1 2 AA Device Type Notification Sensor Generic Device Class Sensor Notification Specific Device Class Routing Sensor Notification Network Operation Reporting Sleeping Slave Firm...

Страница 13: ... Command Class Version 3 highest granted security level Security 2 Command Class Version 1 highest granted security level Supervision Command Class Version 1 non Secure Transport Service Command Class Version 2 non Secure Central Scene Command Class Version 3 highest granted security level Explanation of Z Wave specific terms Controller is a Z Wave device with capabilities to manage the network Co...

Отзывы: