Thanks to its slim design the AEOTEC Door/Window Sensor 7 Pro can be installed unflashy on every 

window. The sensor just has to be installed on the window casement. Additionally, there has to be a slim 

magnet installed closely to the sensor at the window frame. By using a patented method the sensor can 

reliably detect the exact position of the window. 

 

With the potential free input, the Door/Window Sensor can also include other sensors in your Z-Wave 

system. For that, the binary sensor is connected to the potential free input of the sensor. Besides sensors, 

there can also be connected momentary switches, which control scenes in your gateway. 

 

Tripple clicking the tamper button includes (adds) and excludes (removes) the device.  

A single click on the button will wake up the device. The device supports the Z-Wave Security S2 

framework with authenticated and unauthenticated network keys. Please follow the instructions on the 

central controller when including. The device also supports Smart Start. 

Prepare for Installation / Reset 

Please read the user manual before installing the product. 

In order to include (add) a Z-Wave device to a network it 

must be in factory default state.

 Please make 

sure to reset the device into factory default. You can do this by performing an Exclusion operation as 

described below in the manual. Every Z-Wave controller is able to perform this operation however it is 

recommended to use the primary controller of the previous network to make sure the very device is 

excluded properly from this network. 

Reset to factory default 

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should 

only be used when the primary controller is inoperable. 

Once Cover is removed and the tamper switch is tripped, push the tamper for 5 seconds until the RED 

LED blinks once. Then release tamper and push it again for 5 seconds while the RED LED is blinking until 

the GREEN LED blinks once. 

Safety Warning for Batteries 

The product contains batteries. Please remove the batteries when the device is not used. Do not mix 

batteries of different charging level or different brands. 

Installation 

The sensor can be mounted either on the moving part or on the fixed part of a door or a window. 

Mounting can be accomplished either using the tape by peeling off the protection foil or using two 

screws with the holes inside the battery compartment. If the tilt detection on a window (only normal 

windows, no roof windows) shall be used the sensor device must be placed on the moving part of the 

window and the magnet on the window frame.  

The sensor comes with two types of magnets: 

Содержание Aeotec 7 Pro

Страница 1: ...Door Window Sensor 7 Pro ...

Страница 2: ... way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter This device and every other certified Z Wave device can be used together with any other certified Z Wave device regardless of brand and origin as long as both are suited for the same frequency range If a device supports secure ...

Страница 3: ... into factory default You can do this by performing an Exclusion operation as described below in the manual Every Z Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network Reset to factory default This device also allows to be reset without any involvement o...

Страница 4: ...ed Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller is turned into exclusion respective inclusion mode Inclusion and Exclusion is then performed doing a special manual action right on the device Inclusion 1 Open the housing 2 Remove the battery protection 3 Press the tamper on the side of the appliance three times quickly Exclusion 1 Open the h...

Страница 5: ...mper will start the process As a result the GREEN LED will blink two times in case of success and the RED LED will blink two times in case of failure Scene Controller When activated by configuration parameter 14 the device can perform as a scene controller Digital VCC is used to connect the scene button The external dry contact will then act as a scene controller with a total of 7 scenes that can ...

Страница 6: ...firmware over the air The update function needs to be supported by the central controller Once the controller starts the update process perform the following action to confirm the firmware update Wake Up the device by removing the cover Then hit the tamper switch once Association one device controls another device Z Wave devices control other Z Wave devices The relationship between one device cont...

Страница 7: ...0 Setting Description 0 Internal Magnet Sensor Used and scene activation enabled 1 External Terminal Inputs Used and scene activation disabled Note Quick press the button 5 times which can also toggle parameter 1 setting value from 0 1 Parameter 2 Dry Contact Operation Mode This Parameter defines how dry contact will operate with the sensor or switch that is connected to the dry contact terminals ...

Страница 8: ... failure Size 1 Byte Default Value 0 Setting Description 0 Disabled 1 Enabled Parameter 6 2nd Association Group Trigger This parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 2 Size 1 Byte Default Value 0 Setting Description 0 Switch after Open and Close 1 Switch after Open 2 Switch after Close Parameter 7 Command Sent to Devi...

Страница 9: ...escription 0 32400 seconds Parameter 11 Time Delay of Off command frame Off command is sent after a delay defined in this parameter Size 2 Byte Default Value 0 Setting Description 0 32400 seconds Parameter 12 Delay of Tamper Alarm Cancellation Time a tamper alarm is delayed Size 2 Byte Default Value 0 Setting Description 0 32400 seconds Parameter 13 Reporting Tamper Alarm Cancellation This paramet...

Страница 10: ... OFF state Size 1 Byte Default Value 0 Setting Description 0 OFF when sensor is vertical 1 ON when sensor is vertical Parameter 17 5th Association Group Trigger This parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 5 Size 1 Byte Default Value 0 Setting Description 0 Switch after Open and Close 1 Switch after Open 2 Switch aft...

Страница 11: ...lt sensitivity With this parameter you can adjust the tilt sensitivity if the tilt is too low or too strong Value 0 does not disable Tilt Sensor it just sets it to a minimum Size 1 Byte Default Value 50 Setting Description 1 100 Sensitivity Parameter 22 Enalbe disbale Binary Sensor report Backwards compatibility Binary Sensor for door window state Sensor type 0x0A Size 1 Byte Default Value 0 Setti...

Страница 12: ...rameter settings to their default settings 1431655765 Completely factory reset sensor and send device reset locally notification Technical Data Dimensions 28x95x35 mm Hardware Platform ZGM130S IP Class IP 20 Battery Type 1 1 2 AA Device Type Notification Sensor Generic Device Class Sensor Notification Specific Device Class Routing Sensor Notification Network Operation Reporting Sleeping Slave Firm...

Страница 13: ... Command Class Version 3 highest granted security level Security 2 Command Class Version 1 highest granted security level Supervision Command Class Version 1 non Secure Transport Service Command Class Version 2 non Secure Central Scene Command Class Version 3 highest granted security level Explanation of Z Wave specific terms Controller is a Z Wave device with capabilities to manage the network Co...

Отзывы: