Important Information

 

After  all  learning  completed,  User  can  go  back  to  the  ZXT-
510  control page on the gateway for normal operation. 

•  On  the  Gateway  UI,  User  can  only  use  the  Temperature 

range  from  the  mapping  table,  OFF,  ON(RESUME), 
COOL,  HEAT,  DRY  MODE, AUTO MODE and FAN MODE. 

•  If  User  only  learnt  ON(RESUME),  OFF,  or  part  of  the 

settings  according  to  the  above  table,  ZXT-510  will  send 
the  learnt  data  to  the  Air  Conditioner  only.  For  example, 
User  only  learnt  ON(RE-  SUME),  OFF,  22°C  COOL,  24°C 
HEAT,  ZXT-510  will  not  send  the  IR  Data  to  Air Conditioner 
if User set 27°C Cool on the gateway. 

•  User  can  still  use  gateway  to  set  up  Scene  and  Schedule 

with  ZXT-510.  For  example,  to  have  AC  turn  on  at  23°C 
every  day  at  7am,  25°C  at  11pm.  Just  make  sure  the  set 
code is learnt. 

•  The learning mapping table is for split Air Conditioner, which 

Re-  mote  Control  is  with  LCD  Display.  For  Window  type  Air 
Condition-  er  (which  Remote  Control  is  without  LCD 
Display),  the  mapping  table  with  temperatures  do  not  apply, 
due  to  different  type  of  IR  Control  Protocol.  However,  User 
may  still  use  OFF,  ON(RESUME),  DRY,  AUTO  or  FAN  Key 
for Learning. 

•  (Because  the  POWER key  on  the  Original  Remote  (without 

LCD  Display)  is  toggle,  user  can  choose  either  ON  key  or 
OFF  key  to  learn  Power  key.  After  Learning  is  done,  press 
once to turn  on the  Air  Conditioner  if  the  Air  Conditioner  is 
OFF, press  once to turn  OFF if the Air Conditioner is ON) 

Содержание AC MASTER LITE

Страница 1: ...ZXT 510 AC MASTER Lite INSTALLATION GUIDE...

Страница 2: ......

Страница 3: ...3 Setup Automatic Status Report Association to Gateway 7 Step 4 Setup Air Conditioner IR code 7 Other Setup Options through Configuration 14 Support for Association Groups 17 Reset to Factory Default...

Страница 4: ...2 Caution 23...

Страница 5: ...loud stored IR database library ZXT 510 can control different brands and models of air conditioners worldwide ZXT 510 is a security enabled Z Wave plus device A security Enabled Z Wave Plus Controller...

Страница 6: ...4 Product Overview...

Страница 7: ...l interchangeable when setting up your Z Wave network Inclusion Add a Z Wave device to the network Exclusion Remove a Z Wave device from the network Remove To take a device out of a group scene or ass...

Страница 8: ...Rout ing Slave FLiRS mode is targeted for battery operated applica tions and will enter sleep mode frequently in order to conserve battery consumption The response to Z Wave command is not as quick as...

Страница 9: ...ing or awake cannot be changed unless it is exclud ed and re apply the power ZXT 510 can be included and operated in any Z Wave network with other Z Wave certified devices from other manufacturers and...

Страница 10: ...oup 1 max 1 node is default to associate with the primary controller Gateway Hub Controller for AC Master Status change report refer to below for report details Current Room Temperature report in prec...

Страница 11: ...9 and Con figuration Command Class You may refer to below steps to setup the IR code using the configuration options in your gateway...

Страница 12: ...eat Step 2 and 3 to Select the next IR Code on the search list Green Indicator flashes ONCE every time i f receives a command from Gateway Important Information Different brand or model of air conditi...

Страница 13: ...urns ON for in dicating the IR Code Learning Start 4 Aim the Original Air Conditioner Remote at AC Master according to below position within 1 3cm Press Power ON button on the Original Air Conditioner...

Страница 14: ...model Keep away from Incandescent Light or Direct Sunlight during learning Make sure IR Transmitter of your Original Remote alight with learning diode of AC Master you may also slight adjust closer o...

Страница 15: ...COOL 68 F or 69 F COOL 6 21 C COOL 70 F or 71 F COOL 7 22 C COOL 72 F or 73 F COOL 8 23 C COOL 74 F or 75 F COOL 9 24 C COOL 76 F COOL 10 25 C COOL 77 F or 78 F COOL 11 26 C COOL 79 F or 80 F COOL 12...

Страница 16: ...76 F HEAT 24 25 C HEAT 77 F or 78 F HEAT 25 26 C HEAT 79 F or 80 F HEAT 26 27 C HEAT 81 F or 82 F HEAT 27 28 C HEAT 83 F or 84 F HEAT 28 29 C HEAT 85 F HEAT 29 30 C HEAT 86 F HEAT 30 DRY MODE DRY MOD...

Страница 17: ...l use gateway to set up Scene and Schedule with ZXT 510 For example to have AC turn on at 23 C every day at 7am 25 C at 11pm Just make sure the set code is learnt The learning mapping table is for spl...

Страница 18: ...0x00 to 0x04 0 0x00 Idle IR Channel is idle 1 0x01 OK the last learning opera tion was completed successfully 2 0x02 Learning ZXT 510 is busy processing previous learning request 3 0x03 Full All locat...

Страница 19: ...m user can disable the built in IR emitter and use the exter nal IR emitter cable to control each air conditioner 32 0x20 Default 0xFF 0 or 255 0x00 or 0xFF 0 0x00 Disable 255 0xFF Enable Default 1 Co...

Страница 20: ...x1E 0 0x00 Disable AUTO report func tion Default for saving battery life Auto report if room temperature is different from last report 1 0x01 1 F 0 5 C 2 0x02 2 F 1 C 3 0x03 3 F 1 5 C 4 0x04 4 F 2 C 5...

Страница 21: ...cimal numbering format please change it to deci mal value accordingly Mapping Information BASIC Set Value 0x00 will map to Thermostat mode OFF 0x00 BASIC Set Value 0xFF will map to Thermostat mode Res...

Страница 22: ...k primary controller is missing or otherwise inop erable Mounting Required tools and supplies Phillips Screwdriver Drill Drill bit 3 16 for drywall 7 32 for plaster Hammer Pencil Level optional AA Alk...

Страница 23: ...ucture of the mounting location If the location does not have the proper material or struc ture the ZXT 510 can fall and cause an injury Avoid mounting above or near hot surfaces or equipment e g TV H...

Страница 24: ...z ZXT 510KR 865 2MHz ZXT 510IN 868 4MHz ZXT 510CN RF Operating Distance Up to 132ft outdoor line of sight in unobstructed environment Temperature Measuremen t Measurable range 0 C 40 C 32 F 104 F Repo...

Страница 25: ...d parties and any property damage or personal injuries arising from or related to the use of the device Service trips to provide instruction on product use Shipping costs for replacement products This...

Страница 26: ...d and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If thi...

Страница 27: ...l appareil ne doit pas produire de brouillage et l utilisateur de l appareil doit accepter tout brouillage radio lec trique subi m me si le brouillage est susceptible d en comprom ettre le fonctionnem...

Отзывы: