CT200-G1 User Guide
Table 21: Thermostat Recovery Mode
Name
Value
Parameter (8-bit)
0x09
Size (3-bit)
0x01
Configuration Values (8-bit)
Configuration values are bit-encoded.
Table 22: Recovery Mode
Value
Configuration
0x01
Fast Mode
0x02
Economy Mode (DEFAULT)
Temperature Reporting Filter
The Temperature Reporting Filter parameter specifes the upper and lower bounds of the am-
bient temperature reporting. The thermostat will not report ambient temperature changes if
the ambient temperature is below the upper bound or above the lower bound. The ther-
mostat will only send ambient temperature changes if the thermostat has been added to an
association group and the temperature reporting threshold is non-zero.
The
Configuration Set Command
is used to set the value of a configuration parameter.
Table 23: Thermostat Recovery Mode Set Command
Name
Value
Parameter (8-bit)
0x0A
Default Value (1-bit)
If set, then Disabled using - Upper Bound
= 0F - Lower Bound = 124F
Size (3-bit)
0x04
Configuration Values (32-bit)
• Byte 1 = Lower Bound
• Byte 2 = Lower Bound
• Byte 3 = Upper Bound
• Byte 4 = Upper Bound
The Scale (2-bites) field indicates the temperature scale. The Scale is encoded in bit 4
and bit 5 of the byte. For example, binary 00000001 indicates Scale is Celsius, and binary
00001001 indicates Scale is Fahrenheit.
Additional bit-encoded information with Scale. In addition, upper three bits indicate the pre-
cision and are always 0x00. In addition, lower three bits indicate the size and are always
0x01
Table 24: Temperature Scale
Value
Configuration
0x00
Celsius
0x01
Fahrenheit
27
Содержание CT200-G1
Страница 1: ...CT200 G1 User Guide Radio Thermostat Jul 29 2019 ...
Страница 2: ......
Страница 4: ...ii ...
Страница 18: ...CT200 G1 User Guide 14 Chapter 1 Installation Guide ...