Chapter 7: Technical parameters and reference standards

Chapter 7: Technical parameters and reference standards

Internal power supply equipment, non-AP/APG equipment 
(equipment that cannot be used in the presence of flammable 
anesthetic gases mixed with air or flammable anesthetic 
gases mixed with oxygen or nitrous oxide)

Normal working
conditions

Service life

5 years (Except for wearing parts)

Electrical safety
classification

BF application section

Electromagnetic
interference

Electromagnetic interference with other devices has not been 
observed in this product, which complies with the current 
international electromagnetic emission standards. To avoid 
electromagnetic interference in the use environment and affect 
the measurement results, keep away from mobile phones, 
computers, and other household appliances while measuring.

Ambient temperature range: 10℃~40℃;
Indoor use  Relative humidity range: <85%

Equipment type

Note: The dry battery provided with this machine is only used for testing when 
the  device  is  turned  on.  It  is  recommended  to  replace  the  new  alkaline  dry 
battery  to  ensure  that  the  blood  glucose  meter  will  not  work  due  to  battery 
undervoltage during the test when the testing organization needs to test the 
performance of the instrument

Содержание 582

Страница 1: ...Meter Specification model 582 Fiveelectrode technology JIANGSU YUWELL MEDICAL EQUIPMENT SUPPLY CO LTD Sales Center Address Huanyuan East Road No 1 Xuzhuang Software Park Nanjing Jiangsu Province P R...

Страница 2: ...e safe use and accurate detection Note For important information please read this instructions in detail to ensure safe use and accurate detection This product is only used for blood glucose testing a...

Страница 3: ...ucose meter provides replacement within 5 years and lifetime warranty service Please complete your valid information in our warranty card and return it to selling pharmacies distributors or Yuwell you...

Страница 4: ...hapter 7 Technical parameters and reference standards Technical parameters 26 Reference standards 29 Chapter 8 Self monitoring time monitoring frequency and control objectives of blood glucose Self mo...

Страница 5: ...lucose in human whole blood taken from the fingertip capillary It is intended to be used by lay person or clinical site by medical staff This system is for in vitro diagnostic use only The yuwell 582...

Страница 6: ...meals and after meals icons 9 Strip and blood icon add blood or control into the strip 10 Low battery icon 11 Control solution icon 12 Temperature icon 13 Display the date 14 Display the month Note Th...

Страница 7: ...value mmol L or mg dL is calculated and displayed by the blood glucose meter and then stored Side of inserting into meter Blood inlet port Reaction zone Note please purchase Yuwell blood test strips a...

Страница 8: ...The month flashes press the button to set the month press the button to confirm the month and switch to the date setting 3 The date flashes press the button to set the date press the button to confir...

Страница 9: ...t and push the lancet to the bottom of the blood sampling pen holder 3 Twist the protection cap from the lancet Do not shake it left or right to prevent the needle from bending Never throw away the pr...

Страница 10: ...he blood sampling pen is ready Please take blood immediately when the meter is ready and prompts blood collec tion 7 Place the top of the prepared blood sampling pen on the part where the blood is to...

Страница 11: ...gle use please do not re use 13 14 Blood glucose test strip and meter preparation 1 Insert the test strip into the slot of the blood glucose meter and push the test strip to the end Trademarks facing...

Страница 12: ...tes that blood is being collected At this time the date time and Calibration code flash alternately on the screen Set the pre meal post meal and quality control solution by pressing the button Test of...

Страница 13: ...the measurement results and shut down 17 18 Display records In the off state press key the screen displays the latest test results Press key again to display all test results in sequence The blood gl...

Страница 14: ...meals 2 months after meals and 3 months after meals The blood glucose meter automatically shuts down after 15 seconds without operation Whole group deleting Press the two keys together for 3 seconds...

Страница 15: ...etection on your blood glucose meter Note It is forbidden to use expired control solution The scrapping disposal of meters blood glucose test strips lancet batteries and their accessories must comply...

Страница 16: ...rol solution icon settings C Use a non toxic detergent and warm water to clean the blood sampling pen adjustment head and dry thoroughly after cleaning It can also be disinfected with medical alcohol...

Страница 17: ...000 times Chapter 6 Storage and maintenance Please use a clean soft damp cloth to clean the meter use 75 alcohol bleaches or strong cleaners are forbidden It is recommended to disinfect and clean the...

Страница 18: ...ices has not been observed in this product which complies with the current international electromagnetic emission standards To avoid electromagnetic interference in the use environment and affect the...

Страница 19: ...kfast blood glucose 1 2 hours after breakfast Before lunch 1 2 hours after lunch Before and after physical exercise Before dinner 1 2 hours after dinner Before going to bed at night After eating desse...

Страница 20: ...r 2 4 times a day after reaching the treatment goal The blood glucose of patients taking oral medications and lifestyle interventions should be monitored for 2 4 times per week Self monitoring frequen...

Страница 21: ...sed by one person and cannot be used by more than one person The lancet is for one time use only please do not reuse it Avoid contact with lotion oil or dust on blood collection pen Do not immerse the...

Страница 22: ...indicates that you may have severe hyperglycemia Please immediately follow the doctor s instructions for repeated detection or treatment Code Error Blood glucose test results are lower than the detect...

Страница 23: ...does not test after adding blood 1 Confirm whether the test strip is fully inserted into the slot 2 Check whether there is foreign matter on the test strip 3 Blood should be sucked into the blood inle...

Страница 24: ...tive and negative direction of the battery are correct 3 Replace with new battery Note if the above situation can not be ruled out during use or unexpected failures occur please contact Yuwell custome...