Install-Xander_Insert_MASONRY - 2017-06-26.doc www.yunca.co.nz
Page 8 of 12
N.
Floor Protector Reductions
N1.
The floor protector extension from the unit
(Fig. 6)
can be reduced if the unit is
elevated.
(Table 2)
Table 2.
Floor Protector Reductions
for Masonry Installations
Elevation Increase (mm)
0
50
100
150
200
Masonry
350
312
300
300
300
O.
Xander Insert Seismic Fixings
Follow loca
l Council’s specifications.
Prior to installation, ensure the cavity floor is levelled. Also ensure the mantel face
is perpendicular in relationship to the cavity floor.
Ensure the unit is securely fixed using sleeve anchors or similar at the locations
shown in the images on this page.
(Fig. 7)
P.
Xander Flue Spigot Fixing
(Fig. 8)
Note: Access to affix the flue to the flue spigot is as follows:
Note: Outer casing top panel must be installed after the flue is fixed in place.
Fig. 7
Fig. 8