IMPORTANT INFORMATION 

 

I. 

It  is  imperative  that  you  familiarise  yourself with  this  entire  document,  and 
also  ensure  you  have  sufficient knowledge  of  relevant  building  regulations 
prior to proceeding with an installation. 

 

II. 

The appliance and flue system shall be installed in compliance with AS/NZS 
2918:2001 and the appropriate requirements of the relevant building code or 
codes. 

 

III. 

Appliances installed in accordance with this standard shall comply with the 
requirements of AS/NZS 4013 where required by the regulatory authority i.e. 
the  appliance  shall  be  identifiable  by  a  compliance  plate  with  the  marking 
“tested to AS/NZS 4013”.

 

IV. 

Any modification of the appliance that has not been approved in writing by 
the testing authority is considered to be in breach of the approval granted for 
compliance with AS/NZS 4013.

 

V. 

Mixing  of  appliance  or  flue  system  components  from  different  sources,  or 
modifying  the  dimensional  specification  of  components  may  result  in 
hazardous  conditions.  Where  such  action  is  considered,  the  manufacturer 
should be consulted in the first instance. 

 

VI. 

Cracked and broken components e.g. glass panels or insulation panels, may 
render the installation unsafe.

 

 

 

INSTALLATION:  

A.  Competent Trades Persons 

are recommended to carry out all installations (e.g. a 

NZHHA Registered Installer), to obtain maximum performance and safe, efficient heating. 

B.  A  Consent

  is  required  and  we  suggest  you  check  with  Local  Authority  Building 

Inspectors as by-laws do vary from area to area.  

Also notify your Insurance Company that a solid fuel heater has been installed. 

C.  Floor  Protector:

 

–  Projection  of  required  floor  protector  may  be  read  off  the  graph 

and/or table on the next page: 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание TOMMI

Страница 1: ...d in the Operations Manual Using it in any manner not recommended by the manufacturer may result in injury or death FOR UNITS INCLUDING ELECTRICAL CONNECTIONS If the wood burner is permanently connected to an electrical source an isolating switch wall switch must be installed New circuits or modifications may be made if required but must be made using the services of a certified electrician only E...

Страница 2: ...ing by the testing authority is considered to be in breach of the approval granted for compliance with AS NZS 4013 V Mixing of appliance or flue system components from different sources or modifying the dimensional specification of components may result in hazardous conditions Where such action is considered the manufacturer should be consulted in the first instance VI Cracked and broken component...

Страница 3: ...0mm at 475mm or higher above the floor 2 Extend at least 200mm from each side of the fuel loading or ash removal opening unless it forms an abutment with a wall or heat shield at a lesser distance 3 Be constructed of 2 sheets of non combustible materials such as one of the following examples or similar The total combined thickness must not be less than 20mm Examples Hilux 2 x 12mm Eterpan 2 x 15mm...

Страница 4: ...se Note All flue joints must be sealed with flue sealing compound Use stainless steel screws or rivets to join the active flue pipe three equally spaced places at each joint The first length of active flue must be fixed to the flue spigot on the burner with at least one stainless steel screw or rivet The required minimum flue termination height is 4 6m above the floor protector G TOMMI WOODBURNER ...

Страница 5: ...Install TOMMI JUN_2020 2020 06 18 docx www yunca co nz Page 5 of 15 FIG A HEATER DIMENSIONS TOMMI WOODBURNER Not to Scale ...

Страница 6: ...Install TOMMI JUN_2020 2020 06 18 docx www yunca co nz Page 6 of 15 FIG B HEATER POSITION TOMMI WOODBURNER Not to Scale ...

Страница 7: ...Install TOMMI JUN_2020 2020 06 18 docx www yunca co nz Page 7 of 15 FIG C TOMMI FREESTANDING WOODBURNER TYPICAL FLUE INSTALLATION ...

Страница 8: ...ACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS NZS 4013 D MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS WHERE SUCH ACTION IS CONSIDERED THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE E CRACKED AND BROKEN COMPONENTS E G GLASS PANELS OR FIRE BRICKS MAY RENDER THE INSTALL...

Страница 9: ...Install TOMMI JUN_2020 2020 06 18 docx www yunca co nz Page 9 of 15 FIG E MAIN AIR INTAKE DUCT ASSY Not to scale ...

Страница 10: ...d that this is where the fire should sit 3 Transfer this floor position mark to the ceiling directly above using a plumb bob laser or other means Mark a line from this point up and down the slope of the ceiling and a line through the point across the slope forming a cross 4 Accurately determine the actual slope of your ceiling Using the numbers from the supplied Ceiling Tile Frame Cut Out chart ma...

Страница 11: ...imum clearance to the walls at each side is 400mm This is achieved with a parallel distance from each wall to the centre of the flue of 879mm See Fig 2 below Fig 2 Plan View Tommi Installed Diagonally Fig 3 Sloped Ceiling Frame Opening Dimensions ANGLE OPENING W x L 0 335 x 335 5 335 10 340 15 345 20 355 25 370 30 385 35 410 40 435 45 475 ...

Страница 12: ...iling Tile Frame and is correctly positioned up and down slope 9 Cut out the ceiling rectangle You can cut around the outside of the line 10 Confirm the Ceiling Tile Frame will fit in the hole and looks appropriate 11 Frame out the sides of the cut out from within the room or from the ceiling cavity if you have access to support the sides of the Ceiling Tile Frame when installed 12 Install the Cei...

Страница 13: ...lumb bob or laser etc You have some latitude to enlarge the hole and move the Ceiling Tile Frame up or down the ceiling slope as required You may temporarily install the two halves of the Ceiling Tile as described below to determine where the Drop Box has to sit 16 Put a couple of temporary screws through the centre holes of the Drop Box and Ceiling Tile frame flanges allowing for perpendicular ad...

Страница 14: ... REAR Ceiling Tile in position against the Ceiling Tile Frame from the down slope side of the flue or the side closest to the wall and press push pin into the socket Note There is no sliding flange on rear inner ceiling tile it may droop slightly 21 1 Slide the Outer upper Ceiling Tile into the slots of the Ceiling Tile Frame on the upper side of the flue Move the two halves together such that the...

Страница 15: ...touches the Drop Box You can do this from within the ceiling cavity above the ceiling if you have access otherwise do it from within the room below the ceiling 25 Before installing any more sections of Liner and while you can still see the spacers connect the first sections of Inner and Outer Liner together by drilling right through the Outer Liner and spacers and installing screws or rivets This ...

Отзывы: