Install-TOMMI - JUN_2020 - 2020-06-18.docx www.yunca.co.nz
Page 4 of 15
E. Manufacturer
’s Recommended Tested Minimum Clearances From
Combustible Walls:
Tested to AS/NZS 2918 : 2001 by SPECTRUM LABORATORIES LIMITED
Clearance
Rear Clearance (with YUNCA TOMMI FLUE GUARD fitted) from the fan
100mm
Side Clearance (with YUNCA TOMMI FLUE GUARD fitted)
400mm
Corner Clearance (with YUNCA TOMMI FLUE GUARD fitted)
400mm
F. YUNCA TOMMI Flue Kit
(Complies with AS/NZS 2918:2001 Appendix F): FIG A, B & E.
1
. 4.8m x 175mm stainless steel flue.
2
. 3.6m x 225mm galvanised inner liner c/w brackets.
3
. 3.6m x 275mm galvanised outer liner c/w brackets.
4.
1 x ceiling trim (500mm x 500mm)
5
. 1 x liner support, drop box upper section.
6
. 1 x drop box lower section.
7.
1 x weather cap & cowl.
Please Note:
All flue joints must be sealed with flue sealing compound. Use stainless
steel screws or rivets to join the active flue pipe (three equally spaced places at each
joint). The first length of active flue must be fixed to the flue spigot on the burner with at
least one stainless steel screw or rivet. The required minimum flue termination height is
4.6m above the floor protector.
G. TOMMI WOODBURNER Flue Mounted Shield (Flue Guard) Kit. Complies
(with heater) to AS/NZS 2918:2001): Refer FIG A.
1 x flue guard mount.
1 x 1200mm length, insulated, flat, back guard, plus an
optional
extension for
trimming to length, as required.
1 x 1200mm length, “U” section, front guard, plus
optional
extension as required.
Please Note: The Tommi Flue Shield is to be full height within the room.
H. TOMMI WOODBURNER Main Air Intake Assembly.
1 x Outer wall vent cowl.
1 x Air intake round duct
1 x Outer wall vent flange
1 x Damper duct assy.
1 x Flexi-duct.
2 x Flexi-duct clamp 100mm