15.2 PRECAUTION FOR JUMP-START CABLES DISCONNECTING
After the engine has starter, disconnect the jump-start cables in the reverse
order in which they were connected:
1. disconnect one clip of jump-start cable (4) to the engine block of the
problem machine,
2. disconnect one clip of jump-start cable (3) to the negative terminal (-) of
the problem machine,
3. disconnect one clip of jump-start cable (2) to the positive terminal (+) of the
normal machine,
4. disconnect one clip of jump-start cable (1) to the positive terminal (+) of the
problem machine.
15.3 PRECAUTION FOR BATTERY CHARGING WHILE IT IS
ONBOARD
B
ATTERY CHARGING
•
Remove the cables from battery terminals, otherwise the
alternator can be damaged from extra voltage.
•
To allow gas produced while charging escape, take off
all top from battery.
•
If battery over heat (electrolyte exceed 45 °C) suspend
charging for a while.
•
Stop immediately charging when battery is well charged.
If you leave battery under charge too much it may
happen:
a) battery overheat,
b) electrolyte level drop down,
c) battery problem may come in.
•
When connect the battery make sure to connect the
cables correctly. Never mix the cable (+ with - ) it will
damage the electrical components and battery.
Содержание YC135
Страница 2: ......
Страница 4: ...4...
Страница 14: ...14...
Страница 40: ...40...
Страница 51: ...51 5 2 1 Transport blocked All dimensions are in mm they may change without notice...
Страница 95: ...95...
Страница 100: ...100...
Страница 108: ...108...
Страница 110: ...110...
Страница 118: ...118...
Страница 120: ...120...
Страница 124: ...124...
Страница 169: ...169 20 HYDRAULIC SCHEME...
Страница 171: ...171 21 ELECTRICAL SCHEME...
Страница 179: ...179 24 NOTICE...
Страница 180: ...180...