background image

2

Manual scrolling data display using scroll keys;

9

Measurement

Each phase and neutral current measurement
Neutral line with CT.

10

Alarm

PF;
voltage dip/Low voltage;
Temperature near terminal block

11

Tamper inputs

Meter cover open;
Terminal cover open;
Comms module cover open;
Strong magnetic field tamper

12

Communications

RS485 (always present)
IR (always present)
Plug-in module:

Wi-Fine
GPRS
LoRa

Protocol: DLMS

13

Tariff

Multi tariff

14

Maximum demand

Configurable integration period-with auto reset on the
1

st

of every month.Manual reset must also be possible

via secure short code method.MD to be part of scroll
display.

15

Load management

Support second configurable load limit threshold that
becomes active during configurable periods

16

LCD display when no Power

LCD display; when the button is pressed, the battery

should allow the LCD to maintain for 30 seconds when
the meter is not powered

17

Anti-tamper when Neutral missing

when Neutral missing, the meter still can work

batter

y support

18

Standards compliance

IEC62052-11
IEC62053-21
IEC62056-46
IEC62056-61
IEC62053-61

3. LCD Display

3.1 LCD Screen

Содержание D524053

Страница 1: ...Introduction 2 Features and technical Parameters 3 Description 4 Display 5 Connection Diagram 6 Dimensions 7 Installation 8 Safety Instructions Three Phase Four Wire Energy Meter User Manual For D5240...

Страница 2: ...4 wire Direct type Indirect type 2 Accuracy class 1 0 or better active energy 2 0 Reactive Energy 3 Voltage 3 240 415V 4 Frequency 50Hz 5 Ib Imax Direct type 5 100A 6 Min Starting Current Class 1 40mA...

Страница 3: ...igurable integration period with auto reset on the 1st of every month Manual reset must also be possible via secure short code method MD to be part of scroll display 15 Load management Support second...

Страница 4: ...escription A Communication Modem B LCD C Scroll up Turn Page D Scroll down Turn Page E Keypad F IR G Impulse constant H Credit indicator green enough credit red no credit yellow low credit A B C D E F...

Страница 5: ...4 5 Connection Diagram Direct type 6 Meter Dimension 7 Installation Instruction...

Страница 6: ...ix two locating points under the meter with self tapping screws Fig 2 Figure 1 Figure 2 Recommended wire For your reference Safe carrying capacity of rubber or plastic insulated wire 1 specification m...

Страница 7: ...contain all of the safety measures for operation of this equipment module device because special operating conditions local code requirements or local regulations may necessitate further measures Howe...

Страница 8: ...any suggestions pls let us know Subject to technical modifications without notice Copyright Copyright Zhejiang Yongtailong Electronic Co Ltd April 2013 All rights Reserved It is prohibited to pass on...

Страница 9: ...8 Post 314500 Web www ytl e com Tel 0573 88105687 Fax 0573 88100423...